MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40634-019-0199-z

Медицинская библиотека · Journal of experimental orthopaedics · 2019

Reliability of ultrasonography measurement of the anterior talofibular ligament (ATFL) length in healthy subjects (in vivo), based on examiner experience and patient positioning.

Kristen Karl-Heinz, Seilern Und Aspang Jesse, Wiedemann Johannes, Hartenbach Florian, Platzgummer Hannes

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The most common cause of ankle injury is the supination trauma, inflicting a partial or complete rupture of the anterior talofibular ligament (ATFL). Among conventional diagnostic tools and procedures of sports injuries, the method of stress-ultrasonography is reportedly a promising diagnostic tool for examining injuries of the lateral ligaments of the ankle. Preceding studies predominantly examined the comparability of stress-ultrasonography and other established diagnostic tools in terms of efficacy, viability and quality. The purpose of this study was to assess the reliability of stress-ultrasonography of the ATFL based on varying examiner experience and patient positioning.

METHOD: Sixteen healthy subjects were examined by four examiners with differing levels of skill and experience in ultrasonography, ranging from laymen to specialist. Measurements were recorded and interrater correlation coefficient (ICC) was applied in four positions, including a neutral position (A), medial rotation (B), plantar flexion (C) and inversion of the foot (D).

RESULTS

The length of the ATFL was 14.958 ± 2.145 mm in position A, 15.886 ± 1.994 mm in position B, 16.270 ± 1.858 mm in position C and 15.170 ± 1.781 mm in position D. The average length change was 0.928 ± 0.804 mm (6.656 ± 6.299%) in position B, 1.313 ± 1.266 mm (9.746 ± 9.484%) in position C and 0.213 ± 1.807 mm (2.604 ± 12.308%) in position D. The correlation of the combined results of all four investigators was 0.333 for position A, 0.386 for position B, 0.320 for position C and 0.517 for position D. The highest ICC (0.811) was recorded between the orthopedic specialist and the radiology specialist. The lowest ICC (0.299) was recorded between the laymen and the radiology specialist.

CONCLUSION

The reliability of the ATFL examination seems to be exceedingly dependent on the examiner's experience and skill in ultrasonographic (US) diagnostic. Moreover, the inversion positioning of the foot, described by the European Society of Musculoskeletal Radiology (ESSR) yielded the highest measurement reliability.

Для цитирования: Kristen Karl-Heinz, Seilern Und Aspang Jesse, Wiedemann Johannes, Hartenbach Florian, Platzgummer Hannes. Reliability of ultrasonography measurement of the anterior talofibular ligament (ATFL) length in healthy subjects (in vivo), based on examiner experience and patient positioning.. Journal of experimental orthopaedics. 2019. DOI: 10.1186/s40634-019-0199-z.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.