MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm.2007.090

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2007

Diagnostic performance of combined specific urinary proteins and urinary flow cytometry in urinary tract pathology.

Penders Joris, Fiers Tom, Everaert Karel, Barth Joeri, Dhondt Annemieke W, Delanghe Joris R

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Urinalysis comprises three techniques: urinary flow cytometry, test strip analysis and determination of specific urinary proteins. We investigated the diagnostic possibilities of combining these methods for a cohort of patients with a variety of well-documented urological and nephrological pathology.

METHODS

Urinary samples from 407 in- and out-patients with nephrological or urological pathology were retrospectively included in our study. Test strip analysis (URISYS 2400), urinary flow cytometry (UF-100) and urinary protein analysis [albumin, total protein, alpha1-microglobulin (A1M), alpha2-macroglobulin (A2M)] were performed.

RESULTS

In discriminating upper and lower urinary tract infections, A1M and A1M/log(white blood cells) can be used, whereas pathological casts only give poor discrimination. The ratio A2M/log(red blood cells; RBC) allows differentiation between cystitis and pyelonephritis, while glomerular diseases can be recognised by the log(RBCxurinary total protein). Combining A2M and urinary albumin allows the determination of acute prostatitis.

CONCLUSIONS

Using combined parameters provided by various urinalysis techniques, ratios can be proposed with diagnostic value for classifying renal and urological conditions. Possible integration in computer-based knowledge systems may offer valuable information for clinicians dealing with these pathologies.

Для цитирования: Penders Joris, Fiers Tom, Everaert Karel, Barth Joeri, Dhondt Annemieke W, Delanghe Joris R. Diagnostic performance of combined specific urinary proteins and urinary flow cytometry in urinary tract pathology.. Clinical chemistry and laboratory medicine. 2007. DOI: 10.1515/cclm.2007.090.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.