Ipsilateral, non-contiguous femoral fractures involving the femoral neck, shaft, and distal articular region are extremely rare and typically result from high-energy trauma. Their complex nature and rarity contribute to a lack of consensus regarding optimal surgical management.
CASE REPORT: We report the case of a 72-year-old male involved in a high-energy motor vehicle accident who sustained a trifocal femoral fracture: an intracapsular femoral neck fracture (AO/OTA 31-B2, Pauwels type 3), a displaced diaphyseal fracture (AO/OTA 32-A2), and a complete intra-articular distal femoral fracture (AO/OTA 33-C2). Initial management included transtibial traction under a Damage Control Orthopaedics (DCO) protocol, followed by definitive fixation 10 days later using a single-stage stepwise surgical approach. Fixation consisted of an antegrade intramedullary nail (providing stabilization of the femoral neck and shaft fractures), 6.5-mm cannulated screws used exclusively for the intra-articular distal femoral fracture, and a LISS plate for the distal metaphyseal component.
RESULTS
Postoperative recovery was uneventful, with radiographic evidence of full fracture union and no signs of post-traumatic osteoarthritis at final follow-up. Clinical recovery was excellent.
DISCUSSION: This is one of the few reported cases in the literature involving a trifocal femoral fracture with this specific combination. Our surgical strategy allowed absolute stability of the distal articular fracture and relative stability for the shaft and femoral neck. A qualitative literature review revealed no standardized algorithm for implant selection or fixation sequence in such cases. Our experience supports a tailored approach based on fracture pattern, emphasizing the preservation of femoral head vascularity and anatomical reduction of joint surfaces.
CONCLUSION
Trifocal ipsilateral femoral fractures require individualized surgical planning. The described combination of implants-used here for the first time-proved effective and may serve as a reference in similar complex trauma cases.