MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/03007995.2017.1421919

Медицинская библиотека · Current medical research and opinion · 2018

Bleeding pattern difference between levonorgestrel intrauterine system and copper intrauterine devices inserted immediately post-abortion: a multicenter, prospective, observational cohort study in Chinese women.

Chen Xiaoning, Li Qianxi, Wang Xiaoye, Chen Jing, Lv Wen, Shi Bin, Wang Hong, Luo Jianru, Li Jian

Сравнительное исследованиеСтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

To describe the bleeding pattern (primary outcome), side effects, treatment satisfaction and 6 month continuity rates associated with the 52 mg levonorgestrel intrauterine system (LNG-IUS) and the copper intrauterine device (Cu-IUD) inserted immediately after abortion.

METHODS

This multicenter, prospective, observational cohort study enrolled healthy women (aged ≥18 years) inserted with LNG-IUS or Cu-IUD immediately after first-trimester surgical abortion and followed up to 6 months. Bleeding pattern was obtained through daily patient bleeding diaries.

RESULTS

From 2013 to 2014, we enrolled 512 women (LNG-IUS = 312 [median age: 32.0 years] and Cu-IUD = 200 [median age: 30.0 years]) from nine Chinese centers. LNG-IUS resulted in a significantly lower number of bleeding/spotting days in the second 90 day reference period compared with Cu-IUD (median 14.5 vs. 18.0 days, p < .0001). Amenorrhea rate (no bleeding/spotting day in the second 90 day reference period) and no menstrual bleeding rate (absence of bleeding days in the second 90 day reference period) were significantly higher in LNG-IUS compared to Cu-IUD (13.9% vs. 0% and 39.5% vs. 0%; p < .001 for all). No dysmenorrhea was higher at the last follow-up in LNG-IUS users than Cu-IUD users (81.2% vs. 76%; p = .0047). Both treatments had a high satisfaction rate among women at both the follow-up visits, and the majority of them continued with the treatment. The rates of adverse events (e.g. oligomenorrhea, amenorrhea) in the LNG-IUS and Cu-IUD groups were 77.2% and 44.5% (p < .0001), respectively.

CONCLUSION

LNG-IUS post-abortion shows better bleeding patterns, and reduced dysmenorrhea and bleeding amount, but with a similar safety profile compared with Cu-IUD. ClinicalTrials.gov identifier: NCT01958684.

Для цитирования: Chen Xiaoning, Li Qianxi, Wang Xiaoye, Chen Jing, Lv Wen, Shi Bin, Wang Hong, Luo Jianru, Li Jian. Bleeding pattern difference between levonorgestrel intrauterine system and copper intrauterine devices inserted immediately post-abortion: a multicenter, prospective, observational cohort study in Chinese women.. Current medical research and opinion. 2018. DOI: 10.1080/03007995.2017.1421919.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.