Ultrasound-guided out-of-plane approach to the sciatic nerve in dogs: a cadaveric comparison with the caudal in-plane approach.
Аннотация
OBJECTIVES
To assess the feasibility [defined as successful circumferential staining of the sciatic nerve (SN) over > 2 cm] and incidence of needle-nerve contact of a novel ultrasound-guided out-of-plane approach targeting the subepimysial perineural compartment cranial to the SN, compared with the conventional caudocranial in-plane technique.
STUDY
DESIGN
Prospective, randomized, experimental anatomical study.
ANIMALS: Twelve canine cadavers (24 pelvic limbs).
METHODS
Bilateral injections of 0.1 mL kg-1 of a lidocaine-dye mixture were performed at the midthigh level in each canine cadaver, with one limb randomly assigned to the in-plane (caudocranial) approach and the contralateral limb to the out-of-plane (lateromedial) approach. Ultrasound recordings were analyzed for needle-nerve contact and number of attempts to reach the injection site. Anatomical dissections assessed the length of circumferential staining. The incidence of needle-nerve contact between approaches was analyzed using McNemar's test, with statistical significance set at p < 0.05. Data not submitted to statistical testing are presented as median and 25th and 75th percentiles (Q1-Q3).
RESULTS
Needle-nerve contact occurred in 9/12 (75%) in-plane injections but in 0/12 (0%) out-of-plane injections (p = 0.003). The out-of-plane approach required fewer attempts to reach the injection site [1 (1-2)] than the in-plane approach [2.5 (2-3.5)] and a shorter needle insertion depth [2.4 (2.1-3.1)] versus 4.61 (3.6-5.2) cm]. Circumferential staining was achieved in all specimens, with staining lengths of 3.5 (2.8-6.6) cm for the in-plane and 4.3 (3.5-4.9) cm for the out-of-plane approach.
CONCLUSIONS AND CLINICAL RELEVANCE: The ultrasound-guided out-of-plane approach targeting the subepimysial perineural compartment cranial to the SN in dogs consistently achieved circumferential staining without observable needle contact, requiring fewer attempts and a shorter needle path compared with the traditional in-plane technique.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.