MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2011.04.015

Медицинская библиотека · Journal of shoulder and elbow surgery · 2011

Proximal humeral fracture fixation: locking plate construct ± intramedullary fibular allograft.

Chow Roxanne M, Begum Farhana, Beaupre Lauren A, Carey Jason P, Adeeb Samer, Bouliane Martin J

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Locking plate constructs for proximal humeral fractures can fail due to varus collapse, especially in osteoporotic bone with medial cortex comminution. Augmentation, using a fibular allograft as an intramedullary bone peg, may strengthen fixation preventing varus collapse. This study investigated the ability of the augmented locking plate construct to withstand repetitive varus stresses relative to the nonaugmented construct.

MATERIALS AND

METHODS

Proximal humeral fractures with medial comminution were simulated by performing wedge-shaped osteotomies at the surgical neck in cadaveric specimens. For each cadaver (n = 8), 1 humeral fracture was fixated with the locking plate construct alone and the other with the locking plate construct plus ipsilateral fibular autograft augmentation. The humeral head was immobilized and a repetitive, medially directed load was applied to the humeral shaft until construct collapse or until 25000 cycles were completed.

RESULTS

No augmented construct collapsed. In comparison, 6 of 8 nonaugmented constructs collapsed (P < .05). Collapse in the 6 nonaugmented constructs occurred after an average ±SD of 6604 ± 1984 cycles. Screw penetration of the articular surface was found in only 1 of the nonaugmented constructs.

CONCLUSION

Fibular allograft augmentation increased the ability of the locking plate to withstand repetitive varus loading. Clinically, this may assist proximal humeral fracture fixation in osteoporotic bone with medial cortex comminution.

Для цитирования: Chow Roxanne M, Begum Farhana, Beaupre Lauren A, Carey Jason P, Adeeb Samer, Bouliane Martin J. Proximal humeral fracture fixation: locking plate construct ± intramedullary fibular allograft.. Journal of shoulder and elbow surgery. 2011. DOI: 10.1016/j.jse.2011.04.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.