Feasibility and procedural outcomes of ultrasound-guided brachiocephalic vein cannulation in neonates weighing less than 1,000 g: a prospective study.

Grasso Fiorentino, Capasso Antonella, Capasso Letizia, Raimondi Francesco

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate the anatomical feasibility and procedural outcomes of ultrasound-guided right brachiocephalic vein cannulation for placing non-tunnelled centrally inserted central catheters in neonates weighing less than 1,000 g.

METHODS

This single-center, prospective observational study assessed right BCV diameter using high-frequency ultrasound (Phase 1), defining anatomical feasibility as a diameter ≥ 2.0 mm (suitable for a 2 French catheter). Subsequently, ultrasound-guided cannulation was evaluated using a standardized "micro-access" bundle (Phase 2), measuring technical success, first-pass rate, and immediate complications.

RESULTS

Sixty neonates were enrolled (median weight, 865 g [interquartile interval, 620 to 970 g]). Anatomical feasibility was 100% (60/60); median diameter was 2.8 mm (interquartile interval, 2.6 to 3.0 mm). Right brachiocephalic vein diameter was significantly smaller in neonates weighing less than 750 g (n = 22) than in those weighing 750 to 1,000 g (n = 38) (median, 2.6 mm [interquartile interval, 2.4 to 2.7 mm] versus 2.95 mm [interquartile interval, 2.8 to 3.1 mm]; p < 0.001). Fifty-two catheterization procedures were performed in 47 infants. Technical success was 100% (52/52), with a first-pass success rate of 76.9% (40/52). No statistically significant difference in first-pass success was detected between the two weight groups (77.3% [17/22] in < 750 g versus 76.7% [23/30] in ≥ 750 g; p = 1.00). No immediate complications were observed (0/52).

CONCLUSION

Ultrasound-guided right brachiocephalic vein cannulation is anatomically feasible and safe in neonates weighing less than 1,000 g, providing a reproducible central venous access pathway when performed with a standardized micro-access protocol.

WHAT IS KNOWN: • Centrally inserted central catheters offer superior performance compared to peripherally inserted central catheters in infants, although clinical data regarding their placement in micro-preterm neonates remain limited.

WHAT IS NEW: • The right brachiocephalic vein caliber consistently exceeds 2.0 mm in neonates weighing < 1,000 g, and a standardized "micro-access" bundle yields high technical success without immediate mechanical complications.

Для цитирования: Grasso Fiorentino, Capasso Antonella, Capasso Letizia, Raimondi Francesco. Feasibility and procedural outcomes of ultrasound-guided brachiocephalic vein cannulation in neonates weighing less than 1,000 g: a prospective study.. European journal of pediatrics. 2026. DOI: 10.1007/s00431-026-07425-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.