MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00167-022-06873-z

Медицинская библиотека · Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022

3D imaging has good specificity but poor sensitivity for the diagnosis of pathologies of the long head of the biceps: a systematic review and meta-analysis.

Lalevée Matthieu, van Rooij Floris, Nover Luca, Kumble Ankitha, Saffarini Mo, Courage Olivier

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

PURPOSE: To systematically review and meta-analyse the literature to determine which three-dimensional (3D) imaging modality provides the best diagnostic accuracy to detect pathologies of the long head of the biceps tendon (LHBT).

MATERIALS AND

METHODS

A search was performed on PubMed, Embase®, and Cochrane. Studies that compared the diagnostic accuracy of 3D imaging modalities versus arthroscopy for the assessment of LHBT pathologies were included. Studies assessing superior labral anterior posterior (SLAP) lesions were excluded.

RESULTS

Fifteen studies were included; nine were eligible for meta-analysis. Six studies on instability indicated a sensitivity of 0.68 (CI 0.46-0.84) and specificity of 0.76 (CI 0.68-0.82). Four studies on full-thickness tears indicated a sensitivity of 0.56 (CI 0.28-0.81) and specificity of 0.97 (CI 0.93-0.99). Four studies on partial-thickness tears indicated a sensitivity of 0.52 (CI 0.20-0.82) and specificity of 0.64 (CI 0.25-0.91). Two studies on any tear indicated a sensitivity of 0.58 (CI 0.28-0.83) and specificity of 0.99 (CI 0.93-1.00). Only one study on other pathologies indicated a sensitivity of 0.61 and specificity of 0.84.

CONCLUSION

To diagnose LHBT pathologies, 3D imaging modalities overall have low-to-moderate sensitivity, but high-to-excellent specificity. The consistency in reported sensitivity is generally poor, while the consistency and reported specificity is good for the detection of instability, full-thickness tears and any tear, but poor for the detection of partial-thickness tears. 3D imaging may be adequate to rule out LHBT pathologies, but are not sufficiently reliable to confirm the presence of such pathologies.

LEVEL OF EVIDENCE: III.

Для цитирования: Lalevée Matthieu, van Rooij Floris, Nover Luca, Kumble Ankitha, Saffarini Mo, Courage Olivier. 3D imaging has good specificity but poor sensitivity for the diagnosis of pathologies of the long head of the biceps: a systematic review and meta-analysis.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2022. DOI: 10.1007/s00167-022-06873-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.