MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.earlhumdev.2011.02.003

Медицинская библиотека · Early human development · 2011

The relation between umbilical cord characteristics and the outcome of external cephalic version.

Kuppens Simone M I, Waerenburgh Evelyne R, Kooistra Libbe, van der Donk Riet W P, Hasaart Tom H M, Pop Victor J M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Umbilical cords of fetuses in breech presentation differ in length and coiling from their cephalic counterparts and it might be hypothesised that these cord characteristics may in turn affect ECV outcome.

AIM: To investigate the relation between umbilical cord characteristics and the outcome of external cephalic version (ECV).

STUDY

DESIGN

Prospective cohort study.

SUBJECTS: Women (>35 weeks gestation) with a singleton fetus in breech presentation, suitable for external cephalic version. Demographic, lifestyle and obstetrical parameters were assessed at intake. ECV success was based on cephalic presentation on ultrasound post-ECV. Umbilical cord length (UCL) and umbilical coiling index (UCI) were measured after birth.

OUTCOME MEASURE: The relation between umbilical cord characteristics (cord length and coiling) and the success of external cephalic version.

RESULTS

ECV success rate was overall 79/146 (54%), for multiparas 37/46(80%) and for nulliparas 42/100 (42%). Multiple logistic regression showed that UCL (OR: 1.04, CI: 1.01-1.07), nulliparity (OR: 0.20, CI: 0.08-0.51), frank breech (OR: 0.37, 95% CI: 0.15-0.90), body mass index (OR: 0.85, CI: 0.76-0.95), placenta anterior (OR: 0.27, CI: 0.12-0.63) and birth weight (OR: 1.002, CI: 1.001-1.003) were all independently related to ECV success.

CONCLUSIONS

Umbilical cord length is independently related to the outcome of ECV, whereas umbilical coiling index is not.

Для цитирования: Kuppens Simone M I, Waerenburgh Evelyne R, Kooistra Libbe, van der Donk Riet W P, Hasaart Tom H M, Pop Victor J M. The relation between umbilical cord characteristics and the outcome of external cephalic version.. Early human development. 2011. DOI: 10.1016/j.earlhumdev.2011.02.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.