MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000000904

Медицинская библиотека · Journal of cataract and refractive surgery · 2022

Safety and effectiveness of a new ophthalmic viscosurgical device: randomized, controlled study.

Packer Mark, Berdahl John P, Goldberg Damien F, Hosten Lester, Lau George

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the safety and effectiveness of a new dispersive ophthalmic viscosurgical device (OVD) (ClearVisc) compared with an approved dispersive OVD (Viscoat) when used in cataract surgery.

SETTING

16 clinics in the United States.

DESIGN

Prospective multicenter controlled randomized 1:1 (ClearVisc:Viscoat; stratified by site, age group, and cataract severity). Patients and examiners masked.

METHODS

Patients aged 45 years or older with age-related noncomplicated cataract considered amenable to treatment with standard phacoemulsification cataract extraction and intraocular lens (IOL) implantation were included. Patients were randomized to receive either ClearVisc or Viscoat using standard techniques. 5 postoperative visits occurred at 6 hours, 24 hours, 7 days, 1 month, and 3 months. The primary effectiveness outcome was the change in endothelial cell density (ECD) from baseline to 3 months. The primary safety end point was the proportion of patients who experienced at least 1 intraocular pressure (IOP) measurement ≥30 mm Hg at any follow-up visit. Noninferiority was tested. Inflammation and adverse events were evaluated.

RESULTS

372 patients were randomized: 184 patients in the ClearVisc group and 188 patients in the Viscoat group. ClearVisc was noninferior to Viscoat in mean percentage of ECD loss from baseline to 3 months (8.4% and 6.8%, respectively). ClearVisc was significantly noninferior to Viscoat in the proportion of patients with postoperative IOP ≥30 mm Hg at any follow-up visit (17.4% and 20.3%, respectively, P = .0002).

CONCLUSIONS

ClearVisc dispersive OVD provides surgeons with a new option in the continuum of approved dispersive OVDs with beneficial properties as a surgical aid in cataract extraction and IOL implantation.

Для цитирования: Packer Mark, Berdahl John P, Goldberg Damien F, Hosten Lester, Lau George. Safety and effectiveness of a new ophthalmic viscosurgical device: randomized, controlled study.. Journal of cataract and refractive surgery. 2022. DOI: 10.1097/j.jcrs.0000000000000904.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.