MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00256-022-04159-6

Медицинская библиотека · Skeletal radiology · 2022

The robustness of glenohumeral centering measurements in dependence of shoulder rotation and their predictive value in shoulders with rotator cuff tears.

Egli Rainer J, Widmer Emma C J, Waltenspül Manuel, Bouaicha Samy, Sutter Reto

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

De-centering of the shoulder joint on radiographs is used as indicator for severity of rotator cuff tears and as predictor for clinical outcome after surgery. The objective of the study was to assess the effect of malrotation on glenohumeral centering on radiographs and to identify the most reliable parameter for its quantification.

SUBJECTS AND

METHODS

In this retrospective study (2014-2018), 249 shoulders were included: 92 with imaging-confirmed supra- and infraspinatus tears (rupture; 65.2 ± 9.9 years) and 157 without tears (control; 41.1 ± 13.0 years). On radiographs in neutral position and external rotation, we assessed three radiographic parameters to quantify glenohumeral centering: acromiohumeral distance (ACHD), craniocaudal distance of the humeral head and glenoid center (Deutsch), and scapulohumeral arch congruity (Moloney). Non-parametric statistics was performed.

RESULTS

In both positions, only the distance parameters ACHD (< 0.5 mm) and Deutsch (< 1 mm) were comparable in the two study groups rupture and control. Comparing the parameters between the study groups revealed only ACHD to be significantly different with a reduction of more than 2 mm in the rupture group. Among the parameters, ACHD ≤ 6 mm was the only cut-off discriminating rupture (12-21% of the shoulders with ACHD ≤ 6 mm) and control (none of the shoulders with ACHD ≤ 6 mm). Ninety percent of shoulders with ACHD ≤ 6 mm presented with a massive rotator cuff tear (defined as ≥ 67% of the greater tuberosity exposed).

CONCLUSION

Glenohumeral centering assessed by ACHD and Deutsch is not affected by rotation in shoulders with and without rotator cuff tear. An ACHD ≤ 6 mm has a positive predictive value of 90% for a massive rotator cuff tear.

Для цитирования: Egli Rainer J, Widmer Emma C J, Waltenspül Manuel, Bouaicha Samy, Sutter Reto. The robustness of glenohumeral centering measurements in dependence of shoulder rotation and their predictive value in shoulders with rotator cuff tears.. Skeletal radiology. 2022. DOI: 10.1007/s00256-022-04159-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.