MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s1677-5538.ibju.2016.0553

Медицинская библиотека · International braz j urol : official journal of the Brazilian Society of Urology · 2018

Pro - inflammatory cytokines and metalloproteinase activation in polypropylene mesh implant in rat subcutaneous tissue.

Bronzatto Elaine, Riccetto Cássio Luis Zanettini

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

AIMS AND

OBJECTIVES

Polypropylene meshes have been increasingly adopted for correction of pelvic organ prolapse due to its lower recurrence rate when compared to surgeries without meshes. The study of the interaction of these materials with the host tissue may contribute to the development of materials with best biocompatibility and, consequently, less complication rates.

MATERIALS AND

METHODS

The present study compares the inflammatory reaction of standard-weight (SW) and lightweight (LW) meshes (72 g/m216g/m2 respectively), implanted in the abdomen of 20 adult rats, which were euthanized in four or 30 days. Quantification of pro-inflammatory markers, IL-1 and TNF-α, and of metalloproteinases, MMP2 and MMP3, were carried out through immunohistochemistry with AxioVision ® software.

RESULTS

There were no significant differences in the quantification of IL-1 and TNF-α in LW versus SW meshes. However, IL-1 quantification increased along time (30 days >4 days, p=0.0269). Also, MMP-2 quantification was similar to SW and LW and both presented a significant increase along time (30 days >4 days, p < 0.0001). MMP-3 quantification also showed no difference between the SW and LW groups, but increased along time (30 days >4 days, p=0.02).

CONCLUSIONS

Mesh's density did not influence the quantification of pro-inflammatory cytokines IL-1 and TNF-α and metalloproteinases 2 and 3. The increased expression of IL-1, MMP-2 and MMP-3 over time could represent a longstanding inflammatory response after PP mesh implantation. Possibly, the occurrence of adverse events following PP prosthetic implants can be influenced by other factors, not solely related to the amount of implanted material.

Для цитирования: Bronzatto Elaine, Riccetto Cássio Luis Zanettini. Pro - inflammatory cytokines and metalloproteinase activation in polypropylene mesh implant in rat subcutaneous tissue.. International braz j urol : official journal of the Brazilian Society of Urology. 2018. DOI: 10.1590/s1677-5538.ibju.2016.0553.