MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2004.02.085

Медицинская библиотека · The Annals of thoracic surgery · 2004

Magnetic resonance angiographic localization of the artery of Adamkiewicz for spinal cord blood supply.

Kawaharada Nobuyoshi, Morishita Kiyofumi, Hyodoh Hideki, Fujisawa Yasuaki, Fukada Johji, Hachiro Yoshikazu, Kurimoto Yoshihiko, Abe Tomio

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study was to determine whether the artery of Adamkiewicz (ARM) can be detected by magnetic resonance angiography and to determine the usefulness of preoperative magnetic resonance angiography evaluation of the ARM.

METHODS

Between April 2000 and December 2003, 120 patients underwent magnetic resonance angiography for detection of the ARM. The morphology of the anterior spinal artery at the ARM junction, as revealed by magnetic resonance angiography, in 99 patients in whom ARM was preoperatively detected was classified into the following three types: noncontinuation of the anterior spinal artery above the ARM junction (type A), continuation of the anterior spinal artery above and below the ARM junction (type B), and noncontinuation of the anterior spinal artery below the ARM junction (type C).

RESULTS

The ARMs were detected in 99 (83%) of 120 patients, and from a total of 110 ARMs 105 (95%) originated from intercostal arteries branching from the left side and 94 (86%) originated between Th9 and Th11. Two ARMs were found in 11 (11%) of 99 patients in whom ARMs were detected. In 107 patients, who underwent magnetic resonance angiography to reveal the morphology of the anterior spinal artery at the ARM junction, the patterns of the anterior spinal artery were type A in 59 patients (55%), type B in 21 patients (20%), type C in 3 patients (3%) and not classified in 24 patients (22%). No spinal cord injury occurred in patients in whom the ARM had been preoperatively detected.

CONCLUSIONS

Preoperative detection of the ARM is possible by magnetic resonance angiography and is very useful for reducing the incidence of ischemic injury of the spinal cord.

Для цитирования: Kawaharada Nobuyoshi, Morishita Kiyofumi, Hyodoh Hideki, Fujisawa Yasuaki, Fukada Johji, Hachiro Yoshikazu, Kurimoto Yoshihiko, Abe Tomio. Magnetic resonance angiographic localization of the artery of Adamkiewicz for spinal cord blood supply.. The Annals of thoracic surgery. 2004. DOI: 10.1016/j.athoracsur.2004.02.085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.