MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rgmx.2018.10.004

Медицинская библиотека · Revista de gastroenterologia de Mexico (English) · 2019

Endoscopic closure of gastrointestinal perforations and fistulas using the Ovesco Over-The-Scope Clip system at a tertiary care hospital center.

Mosquera-Klinger G, Torres-Rincón R, Jaime-Carvajal J

СтатьяПеревод в очереди

Аннотация

INTRODUCTION AND AIM: Enteric perforations and fistulas are difficult to manage due to comorbidities, poor nutritional status, and anatomic challenges related to multiple interventions in those patients. The use of endoscopic methods as a nonsurgical approach is increasing. The aim of the present study was to describe the clinical experience with the use of the Ovesco Over-The-Scope Clip system in the closure of perforations, fistulas, and other indications in the digestive tract at a tertiary care hospital center.

MATERIALS AND

METHODS

A case series was carried out on patients that underwent lesion closure with the Ovesco clip, within the time frame of January 2015 to December 2017.

RESULTS

The Ovesco clip was used for closure in 14 patients ranging in age from 21-90 years, with different indications: iatrogenic perforations; anastomotic leaks and fistulas; tracheoesophageal fistulas; and esophagogastric perforation. Technical success was achieved in 100% of the patients and clinical success in 78.57%. No complications were reported.

CONCLUSIONS

The Ovesco Over-The-Scope Clip system is a safe and effective method for managing gastrointestinal acute perforations and fistulas.

Для цитирования: Mosquera-Klinger G, Torres-Rincón R, Jaime-Carvajal J. Endoscopic closure of gastrointestinal perforations and fistulas using the Ovesco Over-The-Scope Clip system at a tertiary care hospital center.. Revista de gastroenterologia de Mexico (English). 2019. DOI: 10.1016/j.rgmx.2018.10.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.