MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcu.10194

Медицинская библиотека · Journal of clinical ultrasound : JCU · 2003

Mirror-image artifact mimicking epidural hematoma: usefulness of power Doppler sonography.

Cakmakci Handan, Gulcu Aytac, Zenger M Noyan

Клинический случайСтатьяПеревод в очереди

Аннотация

During sonographic examination, a mirror-like interface can scatter the ultrasound beam, producing mirror-image artifacts. We describe a case of bilateral parietal cephalhematoma in the parietal region of a 2-day-old neonate that mimicked bilateral epidural hematoma on routine sonographic examination. Forceps had been used during delivery, and the neonate had been experiencing episodes of apnea since birth. Gray-scale coronal sonograms showed anechoic structures resembling epidural hematomas in the left and right parietal regions. However, color and power Doppler sonography showed normal vascular findings, thus permitting identification of the mirror-image artifact.

Для цитирования: Cakmakci Handan, Gulcu Aytac, Zenger M Noyan. Mirror-image artifact mimicking epidural hematoma: usefulness of power Doppler sonography.. Journal of clinical ultrasound : JCU. 2003. DOI: 10.1002/jcu.10194.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.