Evaluating cone-beam CT in the diagnosis of suspected scaphoid fractures in the emergency department: preliminary findings.

Colville J G, Ray A, Harris M A, Spencer N, Snaith B

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Scaphoid fractures are challenging to accurately diagnose with delayed and missed diagnoses risking poor patient outcomes. Cone beam CT (CBCT) is an emerging technology facilitating alternative access to multi-planar imaging. The aim of this study was to evaluate the use of early CBCT in the diagnosis of suspected scaphoid fractures presenting via the Emergency Department (ED).

METHODS

In this single centre the imaging pathway was adapted to include early CBCT in adult patients with a persisting high index of clinical suspicion for scaphoid fracture despite normal radiographs. Evaluation of referrals between September 2019 and February 2020 was undertaken. Statistical analysis and temporal pathway metrics were assessed including interrater agreement for CBCT and radiography examinations.

RESULTS

Over the six-month timeframe 100 CBCT wrist scans were performed on 99 adult patients. 94% of CBCT scans were performed within 1 day of referral. 25% of scans demonstrated acute injuries including 12 radius, 6 trapezium and 2 scaphoid fractures. For fracture, CBCT had a sensitivity of 96.2% and specificity of 100%. There was a highly significant difference in interobserver variation between fracture detection on CBCT and radiographs.

CONCLUSION

CBCT heralds the potential for early accurate diagnosis of radiocarpal fractures, at lower cost, shortening clinical pathways and reducing clinical risk in the ED.

Для цитирования: Colville J G, Ray A, Harris M A, Spencer N, Snaith B. Evaluating cone-beam CT in the diagnosis of suspected scaphoid fractures in the emergency department: preliminary findings.. Clinical imaging. 2021. DOI: 10.1016/j.clinimag.2021.12.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.