MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ta.0b013e318058249b

Медицинская библиотека · The Journal of trauma · 2007

The accuracy of thoracic ultrasound for detection of pneumothorax is not sustained over time: a preliminary study.

Dente Christopher J, Ustin Jeffrey, Feliciano David V, Rozycki Grace S, Wyrzykowski Amy D, Nicholas Jeffrey M, Salomone Jeffrey P, Ingram Walter L

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Ultrasound has proven to be very accurate in the diagnosis of pneumothorax in the trauma suite. It is unknown whether this accuracy is maintained over time in patients with a thoracostomy (TT) in place.

METHODS

Hospitalized patients with a TT placed to treat a traumatic pneumothorax underwent serial daily bedside surgeon-performed ultrasound by 1 of 2 experienced surgeon sonographers who were unaware of concomitant X-ray findings. Results were compared with daily chest X-ray films. Data collected included size and day of placement of the chest tube, as well as the results of the serial ultrasounds and the comparative X-ray films.

RESULTS

Fourteen patients (78% men, mean age 33 years) sustained traumatic pneumothorax. The causes included stab wound (9), gunshot wound (3), and rib fracture (2). They underwent 126 (median 7) ultrasound evaluations and were followed between 4 and 26 (median 7) days after injury. Of these exams, 95 had a concomitant chest X-ray film within 1 hour of the ultrasound, thus 190 hemithoraces could be analyzed. Eighty-two ultrasounds were performed for hemithoraces that had no injury or TT in place and all 82 revealed normal pleural sliding. No pneumothoraces were noted on concomitant chest X-ray films (100% accuracy). One hundred eight ultrasounds were performed for hemithoraces that had a TT in place. For the first 24 hours, accuracy remained 100%. After 24 hours, however, sensitivity of ultrasound diagnosis of pneumothorax fell to 55%, specificity fell to 70%, positive predictive value to 43%, and negative predictive value to 79%. This led to an overall accuracy rate for ultrasound examination after 24 hours of 65%.

CONCLUSIONS

Ultrasound evaluation for pneumothorax is very accurate for the first 24 hours after insertion of a TT, but the accuracy, especially the positive predictive value, is not sustained over time, possibly as a result of the formation of intrapleural adhesions.

Для цитирования: Dente Christopher J, Ustin Jeffrey, Feliciano David V, Rozycki Grace S, Wyrzykowski Amy D, Nicholas Jeffrey M, Salomone Jeffrey P, Ingram Walter L. The accuracy of thoracic ultrasound for detection of pneumothorax is not sustained over time: a preliminary study.. The Journal of trauma. 2007. DOI: 10.1097/ta.0b013e318058249b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.