MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2013.11.024

Медицинская библиотека · Journal of shoulder and elbow surgery · 2014

Glenoid perforation does not affect the short-term outcomes of pegged all-polyethylene implants in total shoulder arthroplasty.

Press Cyrus M, O'Connor Daniel P, Elkousy Hussein A, Gartsman Gary M, Edwards T Bradley

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The glenoid vault can be perforated during pegged glenoid preparation in total shoulder arthroplasty. The clinical implications of glenoid vault perforation, however, are unknown. The purpose of this study was to determine the effects of perforation of the glenoid during total shoulder arthroplasty on clinical and radiographic outcomes.

MATERIALS AND

METHODS

Eighteen patients with known intraoperative glenoid perforations were prospectively identified and compared with 34 patients matched by age, gender, diagnosis, and arm dominance during the same period. Patients were evaluated with multiple outcome scores. Radiographs were evaluated for glenoid lucency immediately postoperatively and at final follow-up.

RESULTS

Average follow-up was 28.1 months for the perforated group and 31.2 months for the matched controls. Both groups had significant improvements in outcome scores postoperatively. American Shoulder and Elbow Surgeons scores increased from 39.8 to 91.0 (P < .001) in the perforated group and from 36.9 to 82.6 (P < .001) in the control group. Constant scores increased from 24.4 to 77.4 (P < .001) in the perforated group and from 36.9 to 75.6 (P < .001) in the control group. Ninety-four percent of the perforated group and 80% of the matched controls were satisfied or very satisfied with their result (P = .896). The presence and number of perforations were not related to the American Shoulder and Elbow Surgeons score (P = .549), Constant score (P = .154), or radiographic lucency grade (P = .584).

CONCLUSIONS

Glenoid perforation during pegged glenoid preparation in total shoulder arthroplasty does not seem to have an adverse effect on clinical or radiographic outcomes at an average of 2 years of follow-up.

Для цитирования: Press Cyrus M, O'Connor Daniel P, Elkousy Hussein A, Gartsman Gary M, Edwards T Bradley. Glenoid perforation does not affect the short-term outcomes of pegged all-polyethylene implants in total shoulder arthroplasty.. Journal of shoulder and elbow surgery. 2014. DOI: 10.1016/j.jse.2013.11.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.