MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00404-016-4206-7

Медицинская библиотека · Archives of gynecology and obstetrics · 2016

Neonatal complications in vacuum-assisted vaginal delivery: are they associated with number of pulls, cup detachments, and duration of vacuum application?

Ghidini Alessandro, Stewart Daniel, Pezzullo John C, Locatelli Anna

СтатьяПеревод в очереди

Аннотация

PURPOSE: To explore whether the characteristics of vacuum delivery are associated with the occurrence of head injury and neonatal complications.

METHODS

Retrospectively cohort study of vacuum-assisted attempted vaginal deliveries of singletons. We studied the association of total duration of vacuum application and number of pulls and cup dislodgement with (1) primary outcome: the occurrence of major (subgaleal hemorrhage, skull fracture, and intracranial hemorrhage) or minor (cephalohematoma, scalp laceration more extensive than simple abrasions) neonatal head injuries and (2) secondary outcome: the occurrence of neonatal complications, including 5-min Apgar score <7, umbilical artery pH < 7.10, shoulder dystocia, or need for neonatal intensive care unit admission. Logistic regression analysis was used to control for confounders.

RESULTS

Vacuum-assisted delivery was attempted in 555 women. It was successful in 515 cases, and it failed in 40 (7.2 %). Head injury occurred in 32 (6.2 %) of vaginally delivered neonates, and it was related to duration of vacuum application (P = 0.004) and birth weight (P = 0.048). However, the associations lost a statistical significance at the multivariate analysis. Neonatal complications occurred in 25 cases (5 %), and they were associated with meconium-stained amniotic fluid (P < 0.001) and duration of vacuum application (P = 0.03) at the multivariate analysis. However, most of the complications were actually associated with the need for vacuum delivery rather than the procedure itself.

CONCLUSION

Neonatal head injury after vacuum application is not independently related to total duration of vacuum application, number of pulls, or cup dislodgements.

Для цитирования: Ghidini Alessandro, Stewart Daniel, Pezzullo John C, Locatelli Anna. Neonatal complications in vacuum-assisted vaginal delivery: are they associated with number of pulls, cup detachments, and duration of vacuum application?. Archives of gynecology and obstetrics. 2016. DOI: 10.1007/s00404-016-4206-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.