MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.zemedi.2026.09.002

Медицинская библиотека · Zeitschrift fur medizinische Physik · 2026

Evaluation of the detection accuracy of a fully automated AI-based lesion segmentation tool in whole-body FDG PET/CT for lymphoma.

Masogo Tshegofatso, Wadhwa Palak, Kaoma Chimbabantu, Seebarruth Yashna, Qebetu Milani, Banda Kaluzi, Goorhoo Pryaska, Legodi Khomotso, Kumar Dileep, Sathekge Mike, Ramonaheng Keamogetswe

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This study evaluated an AI-based lesion segmentation tool using a hybrid 2D-3D deep learning model based on the nnUNet architecture with a ResNet18 backbone, incorporating post-processing to reduce false positives and segmentation-related quantitative errors.

METHODS

Whole-body FDG PET/CT scans from 72 lymphoma patients (mean age 39.2 ± 18.6 years; 33 females, 39 males; 43.1% Hodgkin lymphoma, 56.9% non-Hodgkin lymphoma) acquired on a uMI550 digital PET/CT system were retrospectively analysed. Automated AI-based segmentations were compared with manual delineations by experienced physicians. Performance was assessed using F1-score, sensitivity, and positive predictive value. Quantitative agreement for all PET metrics was evaluated using Pearson correlation, concordance correlation coefficient, intraclass correlation coefficient, regression, and Bland-Altman analysis. McNemar's test assessed detection differences. The correlations between DSC and image quality metrics were examined.

RESULTS

A total of 711 AI and 848 manually segmented lesions were analysed. The AI model achieved an excellent DSC (89.2%), sensitivity (82.9) and PPV (96.5) which indicated balanced detection performance. Strong correlations were observed for all quantitative parameters (r > 0.95, p < 0.001; CCC > 0.94; ICC > 0.94; 95% CI: 0.93-0.99), with minimal bias on Bland-Altman analysis. DSC showed a moderate negative correlation with liver SNR (r = -0.40, p < 0.001) and weak correlations with liver SUV metrics.

CONCLUSION

The fully automated AI-based segmentation tool demonstrated good-to-excellent lesion detection accuracy and high quantitative concordance with manual segmentation in whole-body FDG PET/CT for lymphoma patients. Continued model refinement and region-specific training are warranted to enhance detection performance.

Для цитирования: Masogo Tshegofatso, Wadhwa Palak, Kaoma Chimbabantu, Seebarruth Yashna, Qebetu Milani, Banda Kaluzi, Goorhoo Pryaska, Legodi Khomotso, Kumar Dileep, Sathekge Mike, Ramonaheng Keamogetswe. Evaluation of the detection accuracy of a fully automated AI-based lesion segmentation tool in whole-body FDG PET/CT for lymphoma.. Zeitschrift fur medizinische Physik. 2026. DOI: 10.1016/j.zemedi.2026.09.002.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.