MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00002480-200109000-00003

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2001

Acute in vivo testing of an intravascular respiratory support catheter.

Golob J F, Federspiel W J, Merrill T L, Frankowski B J, Litwak K, Russian H, Hattler B G

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

Current treatment for acute respiratory failure (ARF) includes the use of mechanical ventilation and/or extracorporeal membrane oxygenation, both of which can exacerbate lung injury. Intravenous respiratory support, using hollow fiber membranes placed in the vena cava, represents an attractive potential treatment for ARF, which could help reduce or eliminate ventilator induced trauma and/or other problems. Our group has been developing a respiratory support catheter (the Hattler catheter [HC]) that consists of a constrained hollow fiber bundle with a centrally located balloon. The balloon can be pulsated rapidly to increase blood flow across the fibers and decrease diffusional transfer resistance there, thus increasing gas exchange. The purpose of this study was to evaluate the HC in acute animal implants and to compare performance with that achieved in previous ex vivo studies. The HC was implanted into four calves by means of the external jugular vein and placed in the superior and inferior vena cava spanning the right atrium. Gas exchange, hemodynamics, and hematologic parameters were assessed over a range of balloon pulsation rates from 30 to 300 beats/minute. A <10% reduction in cardiac output was associated with catheter insertion and operation. The maximum CO2 exchange rate occurred at the highest pulsation rate and averaged 56 +/- 3 ml/min, or 327 +/- 15 ml/min per m2 when averaged to catheter membrane area, a level comparable to that achieved in the previous ex vivo studies. Balloon pulsation did not produce significant levels of hemolysis, as plasma-free hemoglobin remained below 10-15 mg/dl.

Для цитирования: Golob J F, Federspiel W J, Merrill T L, Frankowski B J, Litwak K, Russian H, Hattler B G. Acute in vivo testing of an intravascular respiratory support catheter.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2001. DOI: 10.1097/00002480-200109000-00003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.