MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1537-2995.2004.04082.x

Медицинская библиотека · Transfusion · 2004

Maternal ABO-mismatched blood for intrauterine transfusion of severe hemolytic disease of the newborn due to anti-Rh17.

Denomme G A, Ryan G, Seaward P G R, Kelly E N, Fernandes B J

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Clinically significant antibodies to high-incident antigens present a challenge in hemolytic disease of the newborn. Antigen-negative blood may be difficult to obtain for intrauterine transfusion (IUT). In these instances, maternal blood is de facto compatible regardless of an ABO mismatch.

CASE REPORT: A group B/D-- woman with a history of hemolytic disease of the newborn due to anti-Rh17 (titer 256) presented to the obstetrical clinic at 12 weeks gestation for management of her third pregnancy. She consented to donate blood for possible IUT.

STUDY DESIGN AND

METHODS

Washed maternal packed cells were suspended in saline to 75 percent Hct and irradiated before transfusion. The fetus was transfused via the intrahepatic vein.

RESULTS

Ultrasound examination at 19 weeks indicated a hydropic fetus. The fetal blood group was O Rh+, direct antiglobulin test 4+, and hemoglobin 22 g per L. A total of 368 mL of maternal blood was transfused during seven procedures. Labor was induced at 38 weeks, and a 2560-g male infant was delivered by Caesarian-section due to fetal distress. The infant grouped as B Rh+, direct antiglobulin test negative. No group O red blood cells were detected. The hemoglobin level was 143 g per L rising to 209 g per L at discharge 3 days later. The indirect bilirubin was 55 micromol/L and remained stable during the hospital stay. Phototherapy was discontinued after 1 day, and the infant was discharged without an exchange or top-up transfusion.

CONCLUSIONS

Maternal ABO-mismatched blood is an alternate source for IUT in instances when antigen-compatible allogenic blood is unavailable.

Для цитирования: Denomme G A, Ryan G, Seaward P G R, Kelly E N, Fernandes B J. Maternal ABO-mismatched blood for intrauterine transfusion of severe hemolytic disease of the newborn due to anti-Rh17.. Transfusion. 2004. DOI: 10.1111/j.1537-2995.2004.04082.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.