MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3969/j.issn.1003-0034.2019.02.017

Медицинская библиотека · Zhongguo gu shang = China journal of orthopaedics and traumatology · 2019

[Finite element analysis of InterTan for the treatment of femoral intertrochanteric fractures].

Hao Lian-Sheng, Guan Tao, Huang Feng, Chen Jian, Mu Sheng-Kai, Zhu Gui-Wei

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To study the biomechanical characteristics of InterTan for the treatment of femoral intertrochanteric fracture of Evans-Jensen IV.

METHODS

Scanning the femur and internal plant of volunteers with spiral CT to obtain DICOM format data. Three-dimensional models of left femur and InterTan were reconstructed by Mimics software. On this basis, a three-dimensional finite element model of internal fixation for Evans-Jensen IV intertrochanteric fracture of femur was established. The stress and microstrain distribution of Von Mses in different models were studied. The biomechanical stability after internal fixation of the Evans Jensen IV femoral intertrochanteric fracture was analyzed.

RESULTS

The stress pattern of the femur of InterTan model was the same as that of the normal femur, which was mainly located on the medial side of the proximal femur and the lower third of the femur. However, the stress of femur in InterTan model was lower than that in the same part of normal femur. The peak stress of the femur in the model was 13.92 MPa, located at the end of the inner plant in contact with the femur. The stress peak of the plant in the model was 146.5 MPa at the lower contact point between the tension nail and the main nail.

CONCLUSIONS

InterTan fixation has obvious biomechanical advantages and is not easy to cause stress fractures in the middle femur in patients with osteopenic Evans-Jensen IV intertrochanteric fractures. In particular, for patients with greater activity in the intertrochanteric fracture of the Evans-Jensen IV femur, InterTan fixation has better stability and provides a theoretical basis for the choice of internal fixation.

Для цитирования: Hao Lian-Sheng, Guan Tao, Huang Feng, Chen Jian, Mu Sheng-Kai, Zhu Gui-Wei. [Finite element analysis of InterTan for the treatment of femoral intertrochanteric fractures].. Zhongguo gu shang = China journal of orthopaedics and traumatology. 2019. DOI: 10.3969/j.issn.1003-0034.2019.02.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.