Journal of prosthodontic research · 2025
Factors associated with the risk of fracture of mandibular overdentures on one or two implants: Findings from a 5-year follow-up.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Leles Cláudio Rodrigues, Silva Lucas Peixoto, Martins Nilva Oliveira, Nascimento Lays Noleto, Azevedo Isabela Kattan Fontinele, McKenna Gerald, Srinivasan Murali
Аннотация
PURPOSE: This was a prospective study conducted alongside a randomized controlled trial (RCT) that evaluated the incidence of fractures and associated risk factors in single-implant overdentures (1-IOD) compared with two-implant overdentures (2-IOD).
METHODS: The participants received either a mandibular 1-IOD or 2-IOD (attachments: Straumann® retentive anchor and elliptical titanium matrix with gold insert; implants: 4.1 mm diameter, Straumann® Standard Plus SLActive® Regular Neck), within the context of a randomized clinical trial. The primary outcome of interest was the incidence of IOD fractures at 5-year follow-up. Prosthetic factors, such as area and cervico-incisal height in the attachment region, and volume at the inter-canine region, were measured. Patient-related factors including age, sex, handgrip strength, manual dexterity, bite force, and chewing performance were assessed. Data analysis included descriptive statistics, bivariate tests, Kaplan-Meier plots, and linear discriminant analysis with log10 transformation for variable normalization.
RESULTS: A total of 47 patients were recruited, and 34 (n = 34, 1-IOD = 16, 2-IOD = 18; mean-age: 63.9 ± 8.6 years; 79.4% women) completed the 5-year follow-up. There were no differences in the incidence of fractures between the 1-IOD and 2-IOD groups (P < 0.05). Fractures were more frequent in younger patients, and reduced cervico-incisal IOD height was significantly associated with fractures (P = 0.040). Linear discriminant analysis predicted fractures with 84.4% accuracy and identified cervico-incisal height and age as key predictors.
CONCLUSIONS: There were no significant differences in the incidence of overdenture fractures between groups. Reduced cervico-incisal denture height in the attachment region of ball-retained IODs was associated with mandibular IOD fractures. Further studies with larger cohorts are recommended to identify additional risk factors for mandibular IODs.
METHODS: The participants received either a mandibular 1-IOD or 2-IOD (attachments: Straumann® retentive anchor and elliptical titanium matrix with gold insert; implants: 4.1 mm diameter, Straumann® Standard Plus SLActive® Regular Neck), within the context of a randomized clinical trial. The primary outcome of interest was the incidence of IOD fractures at 5-year follow-up. Prosthetic factors, such as area and cervico-incisal height in the attachment region, and volume at the inter-canine region, were measured. Patient-related factors including age, sex, handgrip strength, manual dexterity, bite force, and chewing performance were assessed. Data analysis included descriptive statistics, bivariate tests, Kaplan-Meier plots, and linear discriminant analysis with log10 transformation for variable normalization.
RESULTS: A total of 47 patients were recruited, and 34 (n = 34, 1-IOD = 16, 2-IOD = 18; mean-age: 63.9 ± 8.6 years; 79.4% women) completed the 5-year follow-up. There were no differences in the incidence of fractures between the 1-IOD and 2-IOD groups (P < 0.05). Fractures were more frequent in younger patients, and reduced cervico-incisal IOD height was significantly associated with fractures (P = 0.040). Linear discriminant analysis predicted fractures with 84.4% accuracy and identified cervico-incisal height and age as key predictors.
CONCLUSIONS: There were no significant differences in the incidence of overdenture fractures between groups. Reduced cervico-incisal denture height in the attachment region of ball-retained IODs was associated with mandibular IOD fractures. Further studies with larger cohorts are recommended to identify additional risk factors for mandibular IODs.