m+Medelevator.RU
← Поиск публикаций
Journal of prosthodontic research · 2025

Factors associated with the risk of fracture of mandibular overdentures on one or two implants: Findings from a 5-year follow-up.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Leles Cláudio Rodrigues, Silva Lucas Peixoto, Martins Nilva Oliveira, Nascimento Lays Noleto, Azevedo Isabela Kattan Fontinele, McKenna Gerald, Srinivasan Murali

Аннотация

PURPOSE: This was a prospective study conducted alongside a randomized controlled trial (RCT) that evaluated the incidence of fractures and associated risk factors in single-implant overdentures (1-IOD) compared with two-implant overdentures (2-IOD).

METHODS: The participants received either a mandibular 1-IOD or 2-IOD (attachments: Straumann® retentive anchor and elliptical titanium matrix with gold insert; implants: 4.1 mm diameter, Straumann® Standard Plus SLActive® Regular Neck), within the context of a randomized clinical trial. The primary outcome of interest was the incidence of IOD fractures at 5-year follow-up. Prosthetic factors, such as area and cervico-incisal height in the attachment region, and volume at the inter-canine region, were measured. Patient-related factors including age, sex, handgrip strength, manual dexterity, bite force, and chewing performance were assessed. Data analysis included descriptive statistics, bivariate tests, Kaplan-Meier plots, and linear discriminant analysis with log10 transformation for variable normalization.

RESULTS: A total of 47 patients were recruited, and 34 (n = 34, 1-IOD = 16, 2-IOD = 18; mean-age: 63.9 ± 8.6 years; 79.4% women) completed the 5-year follow-up. There were no differences in the incidence of fractures between the 1-IOD and 2-IOD groups (P < 0.05). Fractures were more frequent in younger patients, and reduced cervico-incisal IOD height was significantly associated with fractures (P = 0.040). Linear discriminant analysis predicted fractures with 84.4% accuracy and identified cervico-incisal height and age as key predictors.

CONCLUSIONS: There were no significant differences in the incidence of overdenture fractures between groups. Reduced cervico-incisal denture height in the attachment region of ball-retained IODs was associated with mandibular IOD fractures. Further studies with larger cohorts are recommended to identify additional risk factors for mandibular IODs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты