m+Medelevator.RU
← Поиск публикаций
The Journal of hand surgery · 2021

The Effect of Derotational Kirschner Wires on Fracture Gap Reduction With Variable-Pitch Headless Screws.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lynch Daniel, Mickley John P, Gordon Adam, Roebke Austin J, Goyal Kanu S

Аннотация

PURPOSE: We evaluated the impact of angled derotational Kirschner wires (K-wires) on fracture gap reduction with variable-pitch headless screws.

METHODS: Fully threaded variable-pitch headless screws (20 and 28 mm) were inserted into "normal" bone models of polyurethane blocks. In separate trials, derotational K-wires were inserted at predetermined angles of 0°, 15°, 30°, and 40° and compared with each other, with no K-wire as a control. Fluoroscopic images taken after each screw turn were analyzed. The optimal fracture gap closure, initial screw push-off, and screw back-out gap creation were determined and compared at various derotational K-wire angles.

RESULTS: Initial screw push-off due to screw insertion and screw back-out gap creation were not significantly affected by the angle of the derotational K-wire. With a 20-mm screw, only a 40° derotational K-wire led to significantly less gap closure compared with control and with 0°, 15°, and 30° derotational K-wires. It led to an approximately 60% decrease in gap closure compared with no K-wire. With the 28-mm screw, compared with no K-wire, 15° and 30° derotational K-wires led to statistically significant decreases in gap closure (approximately 25%), whereas a 40° derotational K-wire led to an approximately 60% decrease. With the 28-mm screw, the 40° derotational K-wire also led to a statistically significant smaller gap closure when compared with 0°, 15°, and 30° derotational K-wires.

CONCLUSIONS: A derotational K-wire placed in parallel to the planned trajectory of a headless compression screw does not affect fracture gap closure. With greater angulation of the derotational K-wire, the fracture gap is still closed, but less tightly.

CLINICAL RELEVANCE: Derotational K-wires can help prevent fracture fragment rotation during headless compression screw insertion. At small deviations from parallel (≤30°), fracture gap closure achieved by the screw is minimally affected. At greater angles (ie, 40°), fracture gap closure may be substantially reduced, preventing fracture compression.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты