MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2019.09.035

Медицинская библиотека · Injury · 2019

Radiation exposure during direct versus indirect image acquisition during fluoroscopy-controlled internal fixation of a hip fracture: Results of a randomized controlled trial.

Roukema Gert R, De Jong Louis, Van Rijckevorsel Veronique A J I M, Van Onkelen Robbert S, Bekken Joost A, Van der Vlies Cornelis H, Van Lieshout Esther M M

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Intra-operative image acquisition can be obtained indirectly (via verbal request to a technician) or directly (executed at the tableside, by a surgeon stepping on a foot pedal). Direct image acquisition could reduce the exposure time and thus the risk of radiation damage. The aim of this randomized controlled trial was to compare direct surgeon-controlled fluoroscopy with indirect technician-operated fluoroscopy during internal fixation of a hip fracture.

METHODS

From March 5, 2014 to August 19, 2015, 100 patients who had sustained a hip fracture that required internal fixation were enrolled. Patients were randomized between direct surgeon-controlled image acquisition using a foot pedal (n = 52) and indirect image acquisition by a radiology technician (n = 48). The primary outcome measure was the radiation exposure time; secondary outcome measures were the associated effective radiation dose and the dose area product.

(DAP)

RESULTS

A total of 96 patients (with a median age of 84 years) were enrolled in this study. Eighty-nine (93%) patients had a pertrochanteric fracture. No statistically significant differences between direct image acquisition and indirect image acquisition were found for overall radiation time, total radiation dose or DAP for the total population. When adjusted for potential confounders, a difference in overall radiation time of 18.50 s (95% CI 2.19; 34.81, p = 0.027) was found in favour of indirect image acquisition.

CONCLUSION

This study showed statistically significantly lower radiation duration using indirect fluoroscopy for the total population and the pertrochanteric fracture subgroup when adjusted for several confounders. No significant effect on radiation dose and DAP was found.

Для цитирования: Roukema Gert R, De Jong Louis, Van Rijckevorsel Veronique A J I M, Van Onkelen Robbert S, Bekken Joost A, Van der Vlies Cornelis H, Van Lieshout Esther M M. Radiation exposure during direct versus indirect image acquisition during fluoroscopy-controlled internal fixation of a hip fracture: Results of a randomized controlled trial.. Injury. 2019. DOI: 10.1016/j.injury.2019.09.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.