OBJECTIVE

This study aimed to reassess the effect of prophylactic transcervical amnioinfusion for intrapartum meconium-stained amniotic fluid on meconium aspiration syndrome and other adverse neonatal and maternal outcomes.

DATA SOURCES: From inception to November 2021, a systematic search of the literature was performed in PubMed, Embase, Web of Science, and Scopus databases and gray literature sources.

STUDY ELIGIBILITY CRITERIA: We identified randomized controlled trials of patients with intrapartum moderate to thick meconium-stained amniotic fluid that evaluated the effect of amnioinfusion on adverse neonatal and maternal outcomes.

METHODS

Of note, 2 reviewers independently abstracted data and gauged study quality by assigning a modified Jadad score. Meconium aspiration syndrome constituted the primary outcome. The secondary outcomes were meconium below the cords, Apgar scores of <7 at 5 minutes, neonatal acidosis, cesarean delivery, cesarean delivery for fetal heart rate abnormalities, neonatal intensive care unit admission, and postpartum endometritis. This study calculated the odds ratios with 95% confidence intervals for categorical outcomes and weighted mean differences with 95% confidence intervals for continuous outcomes.

RESULTS

A total of 24 randomized studies with 5994 participants met the inclusion criteria. The overall odds of meconium aspiration syndrome was reduced by 67% in the amnioinfusion group (pooled odds ratio, 0.33; 95% confidence interval, 0.21-0.51). Except for postpartum endometritis, amnioinfusion was associated with a significant reduction in all secondary outcomes.

CONCLUSION

Our study found that the use of intrapartum amnioinfusion in the setting of meconium-stained amniotic fluid significantly reduces the odds of meconium aspiration syndrome and other adverse neonatal outcomes.

Для цитирования: Davis Jessica D, Sanchez-Ramos Luis, McKinney Jordan A, Lin Lifeng, Kaunitz Andrew M. Intrapartum amnioinfusion reduces meconium aspiration syndrome and improves neonatal outcomes in patients with meconium-stained fluid: a systematic review and meta-analysis.. American journal of obstetrics and gynecology. 2023. DOI: 10.1016/j.ajog.2022.07.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.