MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000369391

Медицинская библиотека · Gynecologic and obstetric investigation · 2015

A Pilot Study to Investigate the Efficacy of Fibrin Sealant (Tisseel®) in the Loop Electrosurgical Excision Procedure.

Kim Jin Hwi, Park Tae Chul, Park Geum Ae, Song Jae Yeon, Kim Yeon Hee, Lee Hee Joong, Lee Sung Jong, Lee Keun Ho, Hur Soo Young, Park Jong Sup

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: The objective of the current study was to evaluate the efficacy and feasibility of fibrin sealant (Tisseel®) in the loop electrosurgical excision procedure (LEEP) for cervical intraepithelial neoplasia (CIN 2 or 3).

METHODS

We designed a single-blind, prospective, randomized study in 40 consecutive women undergoing LEEP for CIN 2 or 3 at our institute. Two milliliters of fibrin sealant (Tisseel) was applied to the uterine cervix of 20 women immediately after LEEP surgery (treatment group). We evaluated abdominal pain, vaginal bleeding, vaginal discharge and impairment in daily living after 1 week using visual analogue scale questionnaires and compared the results with those of 20 women who did not receive fibrin sealant (control group).

RESULTS

Among 40 women who returned for a follow-up 1 week after LEEP, 25 women (62.5%) reported at least one moderate to severe postprocedural symptom. The mean duration of moderate to severe vaginal bleeding and impairment in daily living during postoperative week 1 for the treatment group and the control group was 0.3 ± 0.80 versus 1.7 ± 2.36 days (p = 0.015) and 0.9 ± 1.37 versus 3.00 ± 2.62 days (p = 0.060), respectively.

CONCLUSION

Intraoperative application of fibrin sealant (Tisseel) in LEEP can decrease postoperative vaginal bleeding and impairment in daily living.

Для цитирования: Kim Jin Hwi, Park Tae Chul, Park Geum Ae, Song Jae Yeon, Kim Yeon Hee, Lee Hee Joong, Lee Sung Jong, Lee Keun Ho, Hur Soo Young, Park Jong Sup. A Pilot Study to Investigate the Efficacy of Fibrin Sealant (Tisseel®) in the Loop Electrosurgical Excision Procedure.. Gynecologic and obstetric investigation. 2015. DOI: 10.1159/000369391.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.