DOI 10.1097/bot.0000000000001686
Impact of Resident Training Level on Radiation Exposure During Fixation of Proximal Femur Fractures.
Аннотация
OBJECTIVE
To identify whether residents are at greater risk of radiation exposure from intraoperative fluoroscopy while earlier in their training and during more complex procedures.
METHODS
We analyzed 852 extracapsular proximal femur fracture fixation cases. We compared fluoroscopy times by various levels of resident training, fracture type, and implant used. Attending-only cases were used as a control group.
RESULTS
Fluoroscopy times during subtrochanteric fracture fixation (176.1 ± 11.27 seconds) were longer than intertrochanteric (111.4 ± 2.44 seconds) and basicervical fractures (91.49 ± 5.77 seconds). Long nail (150.2 ± 3.75 seconds) times were longer than short (92.3 ± 3.15 seconds) and intermediate (76.45 ± 3.01 seconds) nails. Significantly, more fluoroscopy was used in junior (115.9 ± 4.24 seconds), senior (123.0 ± 6.08 seconds), junior combo (130.6 ± 7.74 seconds), and senior combo cases (131.8 ± 6.11 seconds) compared with the control (94.91 ± 3.91).
CONCLUSION
Orthopaedic surgery residents and attendings must remain aware of radiation exposure secondary to intraoperative fluoroscopy. Appropriate personal protective equipment should be worn, and more experienced surgeons should take a more active role in the complex cases to decrease exposure risk.
LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.