MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijoa.2015.09.002

Медицинская библиотека · International journal of obstetric anesthesia · 2015

Effect of neuraxial technique after inadvertent dural puncture on obstetric outcomes and anesthetic complications.

Jagannathan D K, Arriaga A F, Elterman K G, Kodali B S, Robinson J N, Tsen L C, Palanisamy A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The aim of this study was to evaluate labor and delivery outcomes in parturients with inadvertent dural puncture managed by either insertion of an intrathecal catheter or a resited epidural catheter.

METHODS

This was a retrospective cohort review of 235 parturients who had an inadvertent dural puncture during epidural placement over a six-year period. The primary outcome was the proportion of women with a delayed second stage of labor. Secondary outcomes were the proportion of cesarean deliveries, the proportion of cases resulting in post-dural puncture headache, and the incidence of failed labor analgesia.

RESULTS

Baseline characteristics such as age, body mass index and parity were similar between the two groups. Among the 236 cases of inadvertent dural puncture, 173 women (73%) had an intrathecal catheter placed while 63 women (27%) had the epidural catheter resited. Comparing intrathecal with epidural catheters, there was no observed difference in the proportion of cases of prolonged second stage of labor (13% vs. 16%, P=0.57) and the overall rate of cesarean deliveries (17% vs. 16%, P=0.78). However, we observed a lower rate of post-dural puncture headache in women who had cesarean delivery compared to vaginal delivery (53% vs. 74%, P=0.007). A greater proportion of failed labor analgesia was observed in the intrathecal catheter group (14% vs. 2%, P=0.005).

CONCLUSION

The choice of neuraxial technique following inadvertent dural puncture does not appear to alter the course of labor and delivery. Cesarean delivery decreased the incidence of post-dural puncture headache by 35%. Intrathecal catheters were associated with a higher rate of failed analgesia.

Для цитирования: Jagannathan D K, Arriaga A F, Elterman K G, Kodali B S, Robinson J N, Tsen L C, Palanisamy A. Effect of neuraxial technique after inadvertent dural puncture on obstetric outcomes and anesthetic complications.. International journal of obstetric anesthesia. 2015. DOI: 10.1016/j.ijoa.2015.09.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.