m+Medelevator.RU
← Поиск публикаций
Clinical chemistry and laboratory medicine · 2024

Elevated S100B urine levels predict seizures in infants complicated by perinatal asphyxia and undergoing therapeutic hypothermia.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bersani Iliana, Lapergola Giuseppe, Patacchiola Roberta, D'Adamo Ebe, Stuppia Liborio, de Laurenzi Vincenzo, Damiani Verena, Cataldo Ivana, Clemente Katia, Primavera Adele, Salomone Rita, Barbante Elisabetta, Campi Francesca, Savarese Immacolata, Ronci Sara, Dotta Andrea, Braguglia Annabella, Longo Daniela, Gavilanes Danilo A W, Gazzolo Francesca, Serpero Laura, Strozzi Maria Chiara, Maconi Antonio, Cassinari Maurizio, Libener Roberta, Gazzolo Diego

Аннотация

OBJECTIVES: Seizures (SZ) are one of the main complications occurring in infants undergoing therapeutic hypothermia (TH) due to perinatal asphyxia (PA) and hypoxic ischemic encephalopathy (HIE). Phenobarbital (PB) is the first-line therapeutic strategy, although data on its potential side-effects need elucidation. We investigated whether: i) PB administration in PA-HIE TH-treated infants affects S100B urine levels, and ii) S100B could be a reliable early predictor of SZ.

METHODS: We performed a prospective case-control study in 88 PA-HIE TH infants, complicated (n=44) or not (n=44) by SZ requiring PB treatment. S100B urine levels were measured at 11 predetermined monitoring time-points from first void up to 96-h from birth. Standard-of-care monitoring parameters were also recorded.

RESULTS: S100B significantly increased in the first 24-h independently from HIE severity in the cases who later developed SZ and requested PB treatment. ROC curve analysis showed that S100B, as SZ predictor, at a cut-off of 2.78 μg/L achieved a sensitivity/specificity of 63 and 84 %, positive/negative predictive values of 83 and 64 %.

CONCLUSIONS: The present results offer additional support to the usefulness of S100B as a trustable diagnostic tool in the clinical daily monitoring of therapeutic and pharmacological procedures in infants complicated by PA-HIE.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты