INTRODUCTION

Cardiac perforation is a rare complication of cardiac implantable electronic device (CIED) implantation. Transvenous revision of perforated leads is associated with the risk of cardiac tamponade and death. Little is known about periprocedural complications and outcome of these patients.

METHODS AND

RESULTS

All patients referred to our department with evidence or suspicion of cardiac perforation following CIED implantation underwent chest X-ray, transthoracic echocardiography, device interrogation, and, if necessary, a cardiac computed tomography (CT)-scan to diagnose lead perforation and associated complications. Transvenous lead revision (TLR) was performed in all patients with evidence of lead perforation. Patient characteristics, procedural complications, and outcome were recorded and analyzed. Fifty-six patients (75 ± 10 years, 43% male) were diagnosed with cardiac perforation, 34 patients (61%) early within 30 days post-implantation, and 22 patients (39%) thereafter. The most frequent perforation site was the right ventricular (RV) apex (75%), followed by the RV free wall (16%) and the right atrial appendage (9%). A total of 16 patients (29%) presented with severe complications; 12 patients (21%) with pericardial effusion treated by pericardiocentesis before lead revision and four patients (7%) with hematothorax requiring drainage. Late perforations showed significantly more frequent cardiac tamponades (P = .041). TLR was performed without further complications in 54 patients (96%). None of the patients required surgical treatment or experienced in-hospital death.

CONCLUSIONS

Cardiac perforation following CIED implantation is associated with severe complications in nearly one-third of the cases. Transvenous revision of the perforated lead can safely be performed with a very low complication rate.

Для цитирования: Döring Michael, Müssigbrodt Andreas, Ebert Micaela, Bode Kerstin, Lucas Johannes, Dagres Nikolaos, Hindricks Gerhard, Richter Sergio. Transvenous revision of leads with cardiac perforation following device implantation-Safety, outcome, and complications.. Pacing and clinical electrophysiology : PACE. 2020. DOI: 10.1111/pace.14056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.