Nerve Conduction Studies in Surgical Cubital Tunnel Syndrome Patients.
Аннотация
Background
Electrodiagnostic studies (EDX) serve a prominent role in the diagnostic workup of cubital tunnel syndrome (CBTS), but their reported sensitivity varies widely. The goals of our study were to determine the sensitivity of EDX in a cohort of patients who responded well to surgical cubital tunnel release (CBTR), and whether the implementation of the Association of Neuromuscular and Electrodiagnostic Medicine (AANEM) criteria improves the sensitivity.
Methods
We identified 118 elbows with clinical CBTS who had preoperative EDX and underwent CBTR. The EDX diagnoses were CBTS, ulnar neuropathy (UN), and normal ulnar nerves. We divided the 118 elbows into those that received above-elbow stimulation (XE group) and those that did not (non-XE group). We calculated the sensitivities for all groups and reinterpreted the results according to the AANEM guidelines.
Results
Cubital tunnel release provided significant relief in 93.6% of the elbows. Based on the EDX reports, 11% patients had clear CBTS, 23% had UN, and 66% showed no UN. The sensitivities were 11.7% for CBTS and 34.2% for any UN. In the XE group, the sensitivity of the EDX reports for CBTS and UN climbed to 33.3% and 58.3%, respectively. When we calculated the across-elbow motor nerve conduction velocity, the sensitivity for CBTS and UN was 87.5% and 100%, respectively. The XE and non-XE groups showed no difference except for sex, bilaterality, concomitant carpal tunnel release, and obesity (P < .05).
Conclusion
Implementing AANEM guidelines results in significant improvement in correlation of clinical and electrodiagnostic findings of CBTS.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.