Reproductive health · 2013
Feasibility and safety study of a new device (Odón device) for assisted vaginal deliveries: study protocol.
Протокол клинического исследованияСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
World Health Organization Odon Device Research Group, Schvartzman Javier A, Krupitzki Hugo, Betran Ana Pilar, Requejo Jennifer, Bergel Eduardo, Fiorillo Angel E, Gadow Enrique C, Vizcaino Francisco M, von Petery Felicitas, Althabe Fernando, Belizan Jose, Borruto Franco, Boulvain Michel, Di Renzo Gian Carlo, Gülmezoglu Metin, Hofmeyr Justus, Judge Kevin, Leung Tak Yeung, Nguyen My Huong, Saugstad Ola Didrik, Temmerman Marleen, Treisser Alain, Vayena Effy, Merialdi Mario
Аннотация
BACKGROUND: Intrapartum complications are responsible for approximately half of all maternal deaths, and two million stillbirth and neonatal deaths per year. Prolonged second stage of labour is associated with potentially fatal maternal complications such as haemorrhage and infection and it is a major cause of stillbirth and newborn morbidity and mortality. Currently, the three main options for managing prolonged second stage of labour are forceps, vacuum extractor and caesarean section. All three clinical practices require relatively expensive equipment (e.g., a surgical theatre for caesarean section) and/or highly trained staff which are often not available in low resource settings. The specific aim of the proposed study is to test the safety and feasibility of a new device (Odón device) to effectively deliver the fetus during prolonged second stage of labour. The Odón device is a low-cost technological innovation to facilitate operative vaginal delivery and designed to minimize trauma to the mother and baby. These features combined make it a potentially revolutionary development in obstetrics, particularly for improving intrapartum care and reducing maternal and perinatal morbidity and mortality in low resource settings.
METHODS/DESIGN: This will be a hospital-based, multicenter prospective phase 1 cohort study with no control group. Delivery with the Odón device will be attempted under normal labour and non-emergency conditions on all the women enrolled in the study. One-hundred and thirty pregnant women will be recruited in tertiary care facilities in Argentina. Safety will be assessed by examining maternal and infant outcomes until discharge. Feasibility will be evaluated by observing successful expulsion of the fetal head after one-time application of the device under standardized conditions (full cervical dilation, anterior presentation, +2 station, normal fetal heart rate).
TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ANZCTR). Identifier: ACTRN12613000141741.
METHODS/DESIGN: This will be a hospital-based, multicenter prospective phase 1 cohort study with no control group. Delivery with the Odón device will be attempted under normal labour and non-emergency conditions on all the women enrolled in the study. One-hundred and thirty pregnant women will be recruited in tertiary care facilities in Argentina. Safety will be assessed by examining maternal and infant outcomes until discharge. Feasibility will be evaluated by observing successful expulsion of the fetal head after one-time application of the device under standardized conditions (full cervical dilation, anterior presentation, +2 station, normal fetal heart rate).
TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ANZCTR). Identifier: ACTRN12613000141741.