MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0020-1383(01)00125-5

Медицинская библиотека · Injury · 2001

Osteosynthesis of diaphyseal fractures of the radius and ulna using an internal fixator (PC-Fix). A prospective study.

Fernandez Dell' Oca A A, Masliah Galante R

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

Over a five year period, 121 forearm shaft fractures in 82 patients including nine non unions were fixed using the PC-Fix. Two patients died early; of the remaining 80 patients (119 bones) 96% were followed until bone healing. No non unions or late infections were observed in spite of the fact that no primary bone grafts were used except when treating non unions. In this clinical study with a high follow up rate using a newly developed internal fixator, encouraging overall results were achieved and the technology of monocortical locked screws was proven to be valid.

Для цитирования: Fernandez Dell' Oca A A, Masliah Galante R. Osteosynthesis of diaphyseal fractures of the radius and ulna using an internal fixator (PC-Fix). A prospective study.. Injury. 2001. DOI: 10.1016/s0020-1383(01)00125-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.