DOI 10.1016/j.sleep.2024.08.010
Morphometric measures and desaturations: Proposal for an index with improved accuracy for obstructive sleep apnea screening.
Аннотация
STUDY
OBJECTIVE
To evaluate the sensitivity and specificity of the combined Kushida morphometric model (KMM) and the oxygen desaturation index (ODI) for screening individuals with obstructive sleep apnea.
METHODS
Diagnostic test study with adults >18 years, both sexes, polysomnography, body mass index, neck circumference and intraoral measurements.
RESULTS
144 patients were invited; of these, 75 met the exclusion criteria. 55 individuals presented AHI ≥5 ev/h and 14, an AHI <5 ev/h. Three AHI cut-off points were evaluated: AHI ≥5, ≥15, ≥30 ev/h. When adopting the cut-off point of AHI ≥5 ev/h, the KMM showed sensitivity (SE) = 60.0 %, specificity (SP) = 71.4 % and 95 % confidence interval of the area under the curve (95 % CI of AUC) = 0.655; the combination of KMM and ODI (KMM + ODI) revealed SE = 73.0 %, SP = 71.4 % (95 % CI of AUC = 0.779) and the ODI showed SE = 76.4 % and SP = 92.9 % (95 % CI of AUC = 0.815). At the cut-off point of AHI ≥15 ev/h, the KMM presented SE = 64.1 %, SP = 76.7 % (95 % CI of AUC = 0.735); the KMM + ODI showed SE = 82.1 %, SP = 83.3 % (95 % CI of AUC = 0.895); and the ODI presented SE = 76.9 %, SP = 100.0 % (95 % CI of AUC = 0.903). For the cut-off point of AHI ≥30 ev/h, the KMM showed SE = 56.0 %, SP = 77.2 % (95 % CI of AUC = 0.722); the KMM + ODI revealed SE = 92.0 %, SP = 79.5 % (95 % CI of AUC = 0.926); and the ODI showed SE = 92.0 %, SP = 90.9 % (95 % CI of AUC = 0.941).
CONCLUSION
The combination of oxygen desaturation index and Kushida morphometric model improved the sensitivity and specificity of this model regardless of obstructive sleep apnea severity suggesting greater effectiveness in risk prediction.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.