DOI 10.1055/a-1189-7042

Медицинская библиотека · Deutsche medizinische Wochenschrift (1946) · 2020

[Unexpected increase in extravascular lung water after acute lung injury].

Eckle Veit-Simon, Witzenrath Martin, Müller-Redetzky Holger

СтатьяПеревод в очереди

Аннотация

HISTORY AND CLINICAL FINDING: We report on a 27-year-old female patient presenting with pneumonia and developing acute respiratory distress syndrome. Using transpulmonary thermodilution, an elevated extravascular lung water was detected (17 ml/kg). Patient required lung-protective mechanical ventilation and received antibiotic therapy. Negative fluid balance was targeted. Under this treatment, respiratory function improved, inflammation parameters declined, and extravascular lung water was recurrent (10 ml/kg). Subsequently, extravascular lung water increased to 29 ml/kg.

DIAGNOSIS: In a chest x-ray, the central venous catheter tip was dislocated into the right internal jugular vein. 7 days before, the catheter was shown to be in projection of the Vena cava superior in a previous chest x-ray.

THERAPY AND COURSE: After insertion of a new central venous catheter, extravascular lung water was quantified at 10 ml/kg again. After 10 days of mechanical ventilation the patient was successfully extubated.

CONCLUSION

As mechanism for this catheter dislocation, we propose a Valsalva maneuver or spontaneous movements of the upper body of the patient. Sudden increase in extravascular lung water may reflect central venous catheter tip dislocation and chest x-ray should be considered to verify catheter tip position.

Для цитирования: Eckle Veit-Simon, Witzenrath Martin, Müller-Redetzky Holger. [Unexpected increase in extravascular lung water after acute lung injury].. Deutsche medizinische Wochenschrift (1946). 2020. DOI: 10.1055/a-1189-7042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.