Аннотация

PURPOSE: State-of-the-art AI tools offer automated prostate MR volumetry, potentially improving accuracy and efficiency compared to approximation using the ellipsoid formula (A x P x L x 0.52). However, data on the clinical validity of AI-derived volumetry (AI-V) for PSA density (PSAD)-based risk stratification remain limited. We therefore investigated the correlation of AI-V- and ellipsoid formula volume (EL-V)-calculated PSAD with ISUP group and their diagnostic performance for the detection of clinically significant prostate cancer (csPCa).

MATERIALS AND

METHODS

In this IRB-approved retrospective single-centre study, 3-T prostate MRI datasets of 171 patients (median age 68 years) undergoing TRUS-guided transperineal fusion biopsy were analysed. EL-V was calculated by three readers, while AI-V was obtained using a commercially available AI tool. Associations between PSAD and ISUP group were assessed using Spearman's rho and linear regression, and diagnostic performance using receiver operating characteristic (ROC) analysis and predefined PSAD thresholds.

RESULTS

Both AI-derived and EL-V-calculated PSAD showed significant positive correlations with ISUP group (all p<0.001). For csPCa detection, AI-V-derived and EL-V-calculated PSAD demonstrated overall comparable diagnostic performance, with AI-V-derived PSAD achieving an AUC of 0.79 and EL-V-calculated PSAD showing AUC values ranging from 0.76 to 0.78 across readers. Only one reader demonstrated a significantly lower AUC compared with AI-V-derived PSAD (p=0.002). At predefined PSAD thresholds (0.10-0.20), sensitivity and specificity were comparable between both methods.

CONCLUSION

AI-based prostate volumetry represents a valid alternative to ellipsoid formula-calculated volumetry with non-inferior diagnostic performance for csPCa detection.

Для цитирования: Bayraktaroglu Hüdanur, Heimer Maurice M, Kuhnle J Felix, Lorbeer Roberto, Pfitzinger Paulo, Westhofen Thilo, Stief Christian, Ricke Jens, Cyran Clemens C, Lohse Philipp, Kazmierczak Philipp M. Validation of AI-derived whole prostate volumetry versus ellipsoid formula for PSA density-based risk stratification.. European journal of radiology. 2026. DOI: 10.1016/j.ejrad.2026.113080.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.