MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s25123820

Медицинская библиотека · Sensors (Basel, Switzerland) · 2025

A Portable Insole System for Actively Controlled Offloading of Plantar Pressure for Diabetic Foot Care.

Castro-Martins Pedro, Marques Arcelina, Pinto-Coelho Luís, Fonseca Pedro, Vaz Mário

СтатьяПеревод в очереди

Аннотация

Plantar pressure monitoring is decisive in injury prevention, especially in at-risk populations such as people with diabetic foot. In this context, innovative solutions such as pneumatic insoles can be essential in plantar pressure management. This study describes the development of a variable pressure system that promotes the monitoring, stabilization, and offloading of plantar pressure through a pneumatic insole. This research was also intended to evaluate its ability to redistribute plantar pressure, reduce peak pressure in both static and dynamic conditions, and validate its pressure measurements by comparing the results with those obtained from a pedar® insole. Tests were carried out under both static and dynamic conditions, before and after the pressure stabilization process by air cells and the subsequent pressure offloading. During the validation process, methods were used to evaluate the agreement between measurements obtained by the two systems. The results of the static test showed that pressure stabilization reduced pressure on the heel by 32.43%, distributing it to the metatarsals and toes. After heel pressure offloading, the reduction reached 42.72%. In the dynamic test, despite natural dispersion of the measurements, a trend to reduce the peak pressure in the heel, metatarsals, and toes was observed. Agreement analysis recorded 96.32% in the static test and 94.02% in the dynamic test. The pneumatic insole proved effective in redistributing and reducing plantar pressure, with more evident effects in the static test. Its agreement with the pedar® system reinforces its reliability as a tool for measuring and managing plantar pressure, representing a promising solution for preventing plantar lesions.

Для цитирования: Castro-Martins Pedro, Marques Arcelina, Pinto-Coelho Luís, Fonseca Pedro, Vaz Mário. A Portable Insole System for Actively Controlled Offloading of Plantar Pressure for Diabetic Foot Care.. Sensors (Basel, Switzerland). 2025. DOI: 10.3390/s25123820.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.