MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajog.2023.05.018

Медицинская библиотека · American journal of obstetrics and gynecology · 2023

The OdonAssist inflatable device for assisted vaginal birth-the ASSIST II study (United Kingdom).

Hotton Emily J, Bale Nichola, Rose Claire, White Paul, Wade Julia, Mottet Nicolas, Loose Abi J, Elhodaiby Mohamed, Lenguerrand Erik, Draycott Tim J, Crofts Joanna F, ASSIST II Study Group

Рандомизированное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Decreasing rates of assisted vaginal birth have been paralleled with increasing rates of cesarean deliveries over the last 40 years. The OdonAssist is a novel device for assisted vaginal birth. Iterative changes to clinical parameters, device design, and technique have been made to improve device efficacy and usability.

OBJECTIVE

This study aimed to determine if the feasibility, safety, and efficacy of the OdonAssist device were sufficient to justify conducting a future randomized controlled trial.

STUDY

DESIGN

An open-label nonrandomized study of 104 participants having a clinically indicated assisted vaginal birth using the OdonAssist was undertaken at Southmead Hospital, Bristol, United Kingdom. Data were also collected from participants who consented to participate in the study but for whom trained OdonAssist operators were not available, providing a nested cohort. The primary clinical outcome was the proportion of births successfully expedited with the OdonAssist. Secondary outcomes included clinical, patient-reported, operator-reported, device and health care utilization. Neonatal outcome data were reviewed at day 28, and maternal outcomes were investigated up to day 90. Given that the number of successful OdonAssist births was ≥61 out of 104, the hypothesis of a poor rate of 50% was rejected in favor of a good rate of ≥65%.

RESULTS

Between August 2019 and June 2021, 941 (64%) of the 1471 approached, eligible participants consented to participate. Of these, 104 received the OdonAssist intervention. Birth was assisted in all cephalic vertex fetal positions, at all stations ≥1 cm below the ischial spines (with or without regional analgesia). The OdonAssist was effective in 69 of the 104 (66%) cases, consistent with the hypothesis of a good efficacy rate. There were no serious device-related maternal or neonatal adverse reactions, and there were no serious adverse device effects. Only 4% of neonatal soft tissue bruising in the successful OdonAssist group was considered device-related, as opposed to 20% and 23% in the unsuccessful OdonAssist group and the nested cohort, respectively. Participants reported high birth perception scores. All practitioners found the device use to be straightforward.

CONCLUSION

Recruitment to an interventional study of a new device for assisted vaginal birth is feasible; 64% of eligible participants were willing to participate. The success rate of the OdonAssist was comparable to that of the Kiwi OmniCup when introduced in the same unit in 2002, meeting the threshold for a randomized controlled trial to compare the OdonAssist with current standard practice. There were no disadvantages of study participation in terms of maternal and neonatal outcomes. There were potential advantages of using the OdonAssist, particularly reduced neonatal soft tissue injury. The same application technique is used for all fetal positions, with all operators deeming the device straightforward to use. This study provides important data to inform future study design.

Для цитирования: Hotton Emily J, Bale Nichola, Rose Claire, White Paul, Wade Julia, Mottet Nicolas, Loose Abi J, Elhodaiby Mohamed, Lenguerrand Erik, Draycott Tim J, Crofts Joanna F, ASSIST II Study Group. The OdonAssist inflatable device for assisted vaginal birth-the ASSIST II study (United Kingdom).. American journal of obstetrics and gynecology. 2023. DOI: 10.1016/j.ajog.2023.05.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.