[Surgical revision for complications after gamma3-nailing osteosynthesis of proximal humeral fractures : Follow-up series of 1500 patients].
Аннотация
BACKGROUND
The γ‑nailing system is a widespread intramedullary therapeutic option that has been used for intertrochanteric and subtrochanteric fractures since the late 1980s; however, some reports from the 1990s describing femoral shaft fractures questioned the indications for this system in simple fracture types. Due to increasing numbers of patients treated with this system, the complication rate is continuously falling as confirmed by many recent studies.
OBJECTIVE
Between 2008 and 2013 a total of 1500 operations using the γ‑nailing system were performed at this traumatology department. The standard 200 mm nail was used in 1290 cases and the extended system available from 340 to 440 mm in 210 cases. The aim of this study was to record the excellent results using the standard γ‑nailing system and to confirm the indications of the long intramedullary nailing system (Gamma3®) also for use in complex intertrochanteric and subtrochanteric fractures.
MATERIAL AND
METHODS
All 1500 patients were retrospectively analyzed. Information on epidemiological data, intraoperative and postoperative complications and patient outcome was retrieved from the digital patient medical history. All available radiographs were assessed by a single traumatologist.
RESULTS
The results showed a low complication rate of 5% for surgical complications, mainly caused by cutting out in 34.66%, followed by hematomas in 21.33% and fractures of the nail in 16%. A comparison of the standard and long nailing systems could be carried out, showing a complication rate of 3.64% for the standard system compared to 13.33% for the long γ‑nail system.
CONCLUSION
The γ‑nailing system is a safe treatment option for trochanteric femoral fractures and failure of the implant is associated with high biomechanical forces in unstable fractures. A low complication rate is linked to a thorough surgical technique under consideration of a correct positioning of the implant.