MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00059-020-04910-6

Медицинская библиотека · Herz · 2020

Postcardiac injury syndrome after cardiac implantable electronic device implantation.

Filbey Kevin, Sedaghat-Hamedani Farbod, Kayvanpour Elham, Xynogalos Panagiotis, Scherer Daniel, Meder Benjamin, Katus Hugo A, Zitron Edgar

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Postcardiac injury syndrome (PCIS) is an inflammatory complication that derives from injury to the epicardium, myocardium, or endocardium. It occurs after trauma, myocardial infarction, percutaneous coronary intervention, cardiac surgery, intracardiac ablation, and implantation of cardiac implantable electronic device (CIED). In this study we assessed the incidence of PCIS after CIED implantation and its possible risk factors.

MATERIAL AND

METHODS

All patients who received CIED implantation at Heidelberg University Hospital between 2000 and 2014 were evaluated (n = 4989 patients). Clinical data including age, sex, underlying cardiac disease, type of implanted CIED, location of electrode implantation, clinical symptoms, time of symptom onset of PCIS, therapy, and outcome were extracted and analyzed.

RESULTS

We identified 19 cases of PCIS in 4989 patients, yielding an incidence of 0.38%. The age of patients with PCIS ranged from 39 to 86 years. Dilated cardiomyopathy (DCM) as underlying cardiac disease and right atrial (RA) lead implantation had a significant association with occurrence of PCIS (p = 0.045 in DCM and p < 0.001 in RA lead implantation). Dyspnea, chest pain, dry cough, and fever were the most frequently reported symptoms in patients with PCIS. Pericardial and pleura effusion as well as elevated C‑reactive protein (CRP), increased erythrocyte sedimentation rate (ESR), and leukocytosis were the most common findings.

CONCLUSION

To the best of our knowledge, this is the largest cohort evaluating the incidence of PCIS after CIED implantation. The data show that PCIS is a rare complication after CIED implantation and occurs more frequently in patients with DCM and those with RA lead implantation. Although rare and mostly benign, PCIS can lead to potentially lethal complications and physicians must be aware of its symptoms.

Для цитирования: Filbey Kevin, Sedaghat-Hamedani Farbod, Kayvanpour Elham, Xynogalos Panagiotis, Scherer Daniel, Meder Benjamin, Katus Hugo A, Zitron Edgar. Postcardiac injury syndrome after cardiac implantable electronic device implantation.. Herz. 2020. DOI: 10.1007/s00059-020-04910-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.