OBJECTIVES

To evaluate outcomes after thoracic endovascular aortic repair in young patients sustaining traumatic blunt aortic injury (BAI) using iliac extension stent-grafts because of small aortic diameters measuring <24 mm.

METHODS

Retrospective analysis regarding clinical presentation, trauma management, endovascular techniques and outcome of patients with a small descending aorta involving an iliac extension stent-graft to treat traumatic BAI.

RESULTS

Among 48 patients who suffered a BAI and underwent thoracic endovascular aortic repair, 7 received iliac extension stent-grafts. They were 27.4/[standard deviation (SD): -13.1] years old and 6 out of 7 were male. The iliac extension stent-graft was used as distal stent-graft, and a thoracic stent-graft was used in most patients as proximal extension. We achieved overall technical success in all patients during a procedure lasting 92.6 (SD: 54.9) min. One patient died 2 days after the endovascular procedure of hypoxic brain injury, and another died after 17 days of liver failure. That patient had also suffered a spinal cord injury following the procedure, as the stent-graft had been deployed in Ishimaru Zone 2, and the carotid to subclavian bypass had to be omitted because of his critical condition. Control computed tomographic angiographs was available in 6 patients after 7.7 (SD: 5.1) days and showed no endoleak. The surviving patients were discharged after 18.4 (SD: 13.4) days.

CONCLUSIONS

Treating traumatic BAI using iliac extension stent-grafts in young patients with small aortic diameters is feasible. We observed no mortality caused by the BAI or related to endovascular therapy within this small patient cohort.

Для цитирования: Schibilsky David, Kondov Stoyan, Gottardi Roman, Kreibich Maximilian, Lehane Cornelius, Berger Tim, Beyersdorf Friedhelm, Siepe Matthias, Czerny Martin, Rylski Bartosz. Endovascular treatment of traumatic aortic rupture using iliac extension stent-grafts in patients with small aortic diameters.. Interactive cardiovascular and thoracic surgery. 2022. DOI: 10.1093/icvts/ivab377.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.