MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bjid.2023.102804

Медицинская библиотека · The Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases · 2023

Real-time PCR in the diagnosis of congenital toxoplasmosis.

De La Fuente Villar Bianca Balzano, Gomes Leonardo Henrique Ferreira, Portari Elyzabeth Avvad, Ramos Carla Nasser Patrocinio, Rocha Danielle Nascimento, Pereira José Paulo, Neves Elizabeth de Souza, Guida Letícia da Cunha

СтатьяПеревод в очереди

Аннотация

The diagnosis of congenital toxoplasmosis presents limitations and therefore new options are necessary. The analysis of amniotic fluid by real-time PCR has already proved effective for confirmation of fetal infection. However, its performance in other biological samples is not clear yet. The aim of this study is to better understand the role of real-time PCR in the blood of the mother and newborn as well as in the amniotic fluid and placenta in the diagnosis of congenital toxoplasmosis. This is a descriptive cohort study of pregnant women with toxoplasmosis followed up in Rio de Janeiro, Brazil. Real-time PCR was performed in samples of maternal blood, amniotic fluid, placenta, and blood of newborns. In addition, histopathological examination of placentas was performed, and data collected from babies were collected. 116 pregnant women were followed up and 298 samples were analyzed. One (0.9%) pregnant woman presented positive PCR in the blood, 3 (3.5%) in the amniotic fluid, 1 (2.3%) in the placenta and no newborn had positive PCR in the blood. Histopathological study was suggestive of toxoplasmosis infection in 24 (49%) placentas. Six (5.2%) newborns were diagnosed with congenital toxoplasmosis, and only cases with positive PCR in the amniotic fluid had correlation of the PCR result with the diagnosis of congenital infection. Both maternal and blood samples of newborns and placenta did not prove to be promising in the diagnosis of congenital toxoplasmosis. Further studies are needed to evaluate the real role of molecular diagnosis in other biological materials rather than the amniotic fluid.

Для цитирования: De La Fuente Villar Bianca Balzano, Gomes Leonardo Henrique Ferreira, Portari Elyzabeth Avvad, Ramos Carla Nasser Patrocinio, Rocha Danielle Nascimento, Pereira José Paulo, Neves Elizabeth de Souza, Guida Letícia da Cunha. Real-time PCR in the diagnosis of congenital toxoplasmosis.. The Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases. 2023. DOI: 10.1016/j.bjid.2023.102804.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.