m+Medelevator.RU
← Поиск публикаций
Journal of perinatal medicine · 2024

Fetoscopic laser coagulation for twin-to-twin transfusion syndrome: a comparison of flexible 1.0/1.2 mm fetoscopes with curved sheaths of 2.7/3.3 mm2 vs. 2 mm fetoscopic lens technique with sheaths of 6.6/11.3 mm2.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tchirikov Michael, Zühlke Anja, Schlabritz-Lutsevich Natalia, Entezami Michael, Seliger Gregor, Bergner Michael, Li Weijing, Köninger Angela, Wienke Andreas, Yusupbaev Rustem, Ebert Andreas D

Аннотация

OBJECTIVES: Fetoscopic laser coagulation of placental anastomoses is usually performed for a treatment of twin-to-twin transfusion syndrome (TTTS). A common complication of fetoscopic laser coagulation for TTTS is preterm preliminary rupture of fetal membranes (PPROM) aggravating the neonatal outcome significantly. However, use of an flexible 1 mm fetoscope with an curved sheath could reduce iatrogenic damage of the amniotic membrane and improve neonatal outcomes after laser treatment. The aim of this study was to compare neonatal outcomes using this flexible fetoscope with curved sheath vs. use of a standard lens technique.

METHODS: Outcomes were retrospective analyzed after use of a standard lens fetoscope of 2 mm (sheath 6.63 mm2 or 11.27 mm2 for anterior placenta) and a flexible fetoscope of 1 mm or 1.2 mm (sheath 2.65 mm2 or 3.34 mm2) in two German centers of fetal surgery, performed during 2006-2019.

RESULTS: Neonatal outcome of 247 TTTS patients were analyzed including the rates of double and single fetal survival. The survival of at least one fetus was 97.2 % in the group with the ultrathin technique (n=154) compared to 88.3 % (n=93) in the group with the standard lens fetoscope (p=0.008). Survival of both fetuses was not different between groups (81.0 vs. 75.3 %). The procedure to delivery interval was significantly increased using the ultrathin fetoscope (89.1±35.0 d vs. 71.4±35.4 d, p=0.001) resulting in an increased gestational age at delivery by 11 days on average (231.9±28.1 d vs. 221.1±32.7 d, p=0.012).

CONCLUSIONS: Fetal survival can be significantly increased following TTTS using flexible fetoscope of 1 mm or 1.2 mm (sheath 2.65 mm2 or 3.34 mm2).

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты