Management of scaphoid fractures with CT scanning and virtual fracture clinic pathway reduces need for face-to-face clinic appointments.
Аннотация
INTRODUCTION
Early diagnosis is key to managing scaphoid fractures effectively. Computed tomography (CT) imaging can be effective if plain radiographs are negative. With increasing pressure on face-to-face clinics, consultant-led virtual fracture clinics (VFCs) are becoming increasingly popular. This study evaluates the management of patients with suspected scaphoid fractures using a standardised treatment protocol involving CT imaging and VFC evaluation.
METHODS
The study was conducted at a busy district general hospital. The pathway began in February 2018. Patients presenting to the emergency department with a clinically suspected scaphoid fracture but an indeterminate radiograph had a CT scan, which was then reviewed in the VFC. Patients with a confirmed fracture were seen in a face-to-face clinic; patients without a confirmed fracture were discharged. Patient pathway outcome measures were analysed pre- and post-pathway, and a cost analysis was performed.
RESULTS
A total of 164 pre-pathway patients (93%) were given a face-to-face fracture clinic appointment; 76 were discharged after their first visit. Nine patients seen in clinic had a CT scan and were discharged with no fracture. If these patients had been referred to the VFC, had CT scans and been directly discharged, it would have saved £1,629. A total of 41 patients from the post-pathway group (37%) had a CT scan and were discharged from the VFC. Avoiding face-to-face clinic appointments saved £7,421. Extrapolating, the annual savings would be £29,687.
CONCLUSIONS
This study shows that a VFC/CT pathway to manage patients with a suspected scaphoid fracture is cost-effective. It limits face-to-face appointments by increasing use of CT to exclude fractures.