MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02683555241276565

Медицинская библиотека · Phlebology · 2024

Efficacy of ultrasound in the evaluation of iliac vein stenting.

Clode Hannah, Spencer Elizabeth Brooke, Nelson Jacqueline, Horne Elisabeth S

СтатьяПеревод в очереди

Аннотация

Objectives

The current study evaluated the efficacy of iliac and IVC ultrasound alone for follow-up evaluation of iliac vein stents in patients with pelvic venous disorders or iliac occlusion from chronic deep vein thrombosis.

Methods

A retrospective single site cohort study was conducted by evaluating the most recent 100 iliac vein and inferior vena cava ultrasounds in patients who had undergone iliac vein stenting. Inclusion criteria included a history of iliac vein stent placement. Exclusion criteria included patients under 18-years-old, duplicates of the same patient, and pregnancy at the time of ultrasound. The degree of visualization for color flow, gray scale, and phasicity were determined and classified into the following categories: complete, partial, or none. In addition, each chart was assessed for external compression, in-stent narrowing, and requirements for further imaging.

Results

Of the 100 iliac vein and IVC ultrasounds assessed in this review, 99 of the ultrasounds were sufficient for evaluation during follow-up visits without requiring further investigation. Within this study cohort, the average follow-up time was 22 months. The average participant body mass index was 27.6. One iliac vein and IVC ultrasound was considered inadequate for follow-up evaluation and required further imaging.

Conclusion

The use of iliac and IVC venous doppler ultrasound alone in the follow-up evaluation of iliac stent patency is effective and noninvasive and avoids unnecessary radiation exposure and cost.

Для цитирования: Clode Hannah, Spencer Elizabeth Brooke, Nelson Jacqueline, Horne Elisabeth S. Efficacy of ultrasound in the evaluation of iliac vein stenting.. Phlebology. 2024. DOI: 10.1177/02683555241276565.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.