MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2015.06.125

Медицинская библиотека · The Journal of hand surgery · 2015

A Comparison of K-Wire Versus Screw Fixation on the Outcomes of Distal Phalanx Fractures.

Hay Robyn Aik Siew, Tay Shian Chao

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To compare K-wire and screw fixation of distal phalanx (DP) fractures with respect to union and functional outcome.

METHODS

This retrospective study identified patients with DP fractures from a clinic registry taken from 2007 to 2013. Clinical data collected included patient demographics, range of motion (ROM), removal of implant (ROI), and complications. Radiographic data collected included fracture type, location, configuration, fracture displacement, and radiographic union. Statistical analysis was done using a chi-squared test for categorical variables and paired Student's t test for continuous variables.

RESULTS

A total of 172 patients with DP fractures were seen in our clinic between 2007 and 2013. Of these, 141 patients were managed conservatively and 31 patients had surgery for 33 DP fractures, of which 12 had K-wire and 21 had screw fixation. Mean union incidence for screw was 100% compared with 83% for K-wire. Time to union was 2.4 months for screw fixation compared with 4.1 months for K-wire fixation. ROM for screw fixation was significantly better (60°) compared with K-wire fixation (45°). ROM for non-transarticular K-wire (46°) was similar to transarticular K-wire (44°). ROI was performed in 52% of patients with screw fixation. Other than fingertip tenderness, which resolved after ROI, no other complications were noted.

CONCLUSIONS

Our study showed that the union incidence and time to union for screw fixation were comparable to those for K-wire fixation. Screw fixation of DP fractures resulted in greater distal interphalangeal joint motion compared with K-wire fixation but required removal in half of cases.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic III.

Для цитирования: Hay Robyn Aik Siew, Tay Shian Chao. A Comparison of K-Wire Versus Screw Fixation on the Outcomes of Distal Phalanx Fractures.. The Journal of hand surgery. 2015. DOI: 10.1016/j.jhsa.2015.06.125.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.