MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina61081382

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2025

A Comparative Study of Brain Injury Biomarker S100β During General and Spinal Anesthesia for Caesarean Delivery: A Prospective Study.

Banzar Mungun, Erdenebileg Nasantogtokh, Surjavkhlan Tulgaa, Jamsranjav Enkhtsetseg, Janlav Munkhtsetseg, Lundeg Ganbold

СтатьяНаблюдательное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

Background and

Objectives

Anesthetic agents may influence brain function, and emerging evidence suggests possible neurotoxicity under certain conditions. S100β is a well-established biomarker of brain injury and blood-brain barrier disruption, and its prolonged elevation beyond 6-12 h, despite a short half-life, may indicate ongoing neuronal injury. Its use in cesarean section (C-section) remains limited, despite the potential neurological implications of both surgical stress and anesthetic technique. This study evaluates potential brain injury during caesarean section by comparing maternal and neonatal S100β levels under general and spinal anesthesia. Materials and

Methods

This observational prospective study compared changes in the S100β brain damage biomarker in maternal (pre- and post-surgery) and umbilical artery blood during elective c-sections under general or spinal anesthesia. The 60 parturient women who underwent a C-section from 1 July 2021 to 30 December 2023 were evenly distributed into 2 groups: General anesthesia (GA) (n = 30) and Spinal anesthesia (SA) group (n = 30). It included healthy term pregnant women aged 18-40, ASA I-II and excluded those with major comorbidities or emergency conditions.

Results

S100β concentrations slightly increased once the C-section was over in both the SA and GA groups, but without notable differences. In the SA and GA groups, preoperative S100β concentration in maternal blood was 195.1 ± 36.2 ng/L, 193.0 ± 54.3 ng/L, then increased to 200.9 ± 42.9 ng/L, 197.0 ± 42.7 at the end of operation. There was no statistically significant difference in S100β concentrations between the spinal and general anesthesia groups (p = 0.86).

Conclusions

S100β concentrations slightly increased after C-section in both groups. The form of anesthesia seems to be irrelevant for the S100β level. However, further research is needed to confirm these findings and fully evaluate any potential long-term effects.

Для цитирования: Banzar Mungun, Erdenebileg Nasantogtokh, Surjavkhlan Tulgaa, Jamsranjav Enkhtsetseg, Janlav Munkhtsetseg, Lundeg Ganbold. A Comparative Study of Brain Injury Biomarker S100β During General and Spinal Anesthesia for Caesarean Delivery: A Prospective Study.. Medicina (Kaunas, Lithuania). 2025. DOI: 10.3390/medicina61081382.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.