MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcla.22070

Медицинская библиотека · Journal of clinical laboratory analysis · 2016

Change of cystatin C values in preterm infants with asphyxia-From two centers of China.

Yang Yang, Wu Yue, Pan Jing-Jing, Cheng Rui

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To explore the values of cystatin C (Cys-C) in asphyxial preterm babies as an effective endogenous marker of renal function.

METHODS

After birth, preterm infants with 5-minute Apgar score <8 were included into the asphyxia group. Finally, 276 preterm infants born in two neonatal intensive care units were studied (including 78 babies in the asphyxia group and 198 babies in the control group). Blood samples were obtained from peripheral veins on day 1, day 7, and day 28 when routine blood screening tests were performed.

RESULTS

In first day samples, the mean levels of Cys-C were 2.21 (1.49-2.98) mg/L with gestational age (GA) >32, 1.94 (1.37-2.76) mg/L with GA 28-32, and 1.87 (1.49-2.13) mg/L with GA <28 in the asphyxia group. In seventh day samples, the mean levels of Cys-C were 2.35 (1.57-3.26) mg/L with GA>32, 2.07 (1.42-2.90) mg/L with GA 28-32, and 1.69 (1.13-2.04) mg/L with GA <28. In twenty-eighth day samples, the mean levels of Cys-C were 1.92 (1.61-2.13) mg/L with GA>32, 1.79 (1.29-1.84) mg/L with GA 28-32, and 1.66 (1.21-2.10) mg/L GA <28. There were significant differences not only between the asphyxia and control groups, but also between the mild, moderate, and severe asphyxia groups.

CONCLUSION

Cys-C has a good distinguishability in asphyxial neonates in spite of gestational age or birth weight in the Chinese population. Further studies with large numbers of cases are required to assess whether Cys-C could replace creatinine (Cr) and blood urea nitrogen (BUN) as an endogenous marker of renal function.

Для цитирования: Yang Yang, Wu Yue, Pan Jing-Jing, Cheng Rui. Change of cystatin C values in preterm infants with asphyxia-From two centers of China.. Journal of clinical laboratory analysis. 2016. DOI: 10.1002/jcla.22070.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.